STJH-DIRECT-EXPANSION-COOLING-COIL-8ROW

Direct-Expansion Cooling Coil Eight-Row

The deepest DX evaporator in the group for high latent loads and low leaving-air temperatures.
  • Eight-row maximum depth
  • 13.5 in published casing
  • High-latent counterflow design
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This eight-row evaporator extends the casing to 13.5 in and carries the greatest selected refrigerant circuit and surface area. Approximately 500 fpm is a common face-velocity basis, subject to wet-coil carryover and performance rating. It is intended for high-outdoor-air and precision-conditioning systems where deeper cooling justifies the greater air pressure drop, condensate production and refrigerant distribution complexity.

الخصائص الرئيسية

Maximum latent capability

The deep cold surface promotes lower leaving temperature and greater moisture removal.

Expanded refrigerant circuiting

Additional parallel circuits distribute capacity across a large evaporator face.

Precision make-up-air duty

The core supports demanding cleanroom supply conditions that shallow DX coils cannot reach.

المعلمات الفنية

Tube Rows8
Casing Depth13.5 in
Recommended Face VelocityApproximately 500 fpm
CircuitingCounterflow DX
Tube MaterialCopper for halocarbon refrigerant
Fin MaterialAluminum by standard selection
Refrigerant CircuitsMultiple circuits sized to duty
Condensate ManagementDeep drain pan and optional eliminator
Primary DutyHigh-latent precision cooling
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For high-latent cleanroom make-up air, low-temperature DX supply systems and precision manufacturing ventilation.

Solutions for Your Application

Oil return becomes unreliable through numerous low-load refrigerant circuits.Size circuit velocity and staging for part-load operation and coordinate distributor and suction-header geometry.
The deep wet core produces unacceptable fan loss and water carryover.Rate the complete coil wet, enlarge face area and add an eliminator where the selected velocity requires it.

الخيارات المتاحة

Confirm refrigerant, load profile, suction conditions, circuits, distributors, face size, fin spacing, coating, casing and drainage.

Planning a Direct-Expansion Cooling Coil Eight-Row specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.