Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Centrifugal Roof Exhaust Fan 2037 CFM
STJH-CENTRIFUGAL-ROOF-EXHAUST-FAN-2037CFM

Centrifugal Roof Exhaust Fan 2037 CFM

A medium direct-drive upblast fan with variable-speed capacity for laboratory and clean manufacturing exhaust.
  • 581-2037 CFM range
  • 1/2 hp variable-speed motor
  • 19 x 19 in curb cap
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The medium upblast fan provides 581-2037 CFM with a 1/2 hp variable-speed motor while retaining a 19 x 19 in curb cap. Its larger wheel and motor section give nearly twice the maximum airflow of the compact model without increasing the curb footprint. Speed control supports pressure or airflow balancing, but the selected control range must keep the motor and wheel within their approved operating envelope.

Các tính năng chính

Medium roof-exhaust capacity

The larger direct-drive assembly supports laboratory and clean manufacturing exhaust branches.

Variable airflow control

Motor speed can be adjusted to maintain the required exhaust or room-pressure setpoint.

Shared compact curb size

Higher airflow is achieved while retaining the same nominal curb cap as the smaller fan.

Thông số kỹ thuật

Airflow Range581-2037 CFM
Motor1/2 hp
DriveDirect variable speed
Curb Cap19 x 19 in
DischargeCentrifugal upblast
InstallationRoof curb mounted
ControlCompatible variable-speed input
WheelLarger direct-drive centrifugal wheel
Primary DutyMedium general exhaust
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For medium clean manufacturing, laboratory and healthcare roof exhaust where variable airflow supports room-pressure control.

Solutions for Your Application

Reducing speed too far allows backflow or loses required negative room pressure.Set a validated minimum speed and use airflow or pressure feedback with alarm limits.
The existing 19 in curb cannot carry the larger fan's weight or wind load.Verify curb structure and anchorage for the selected unit and local roof conditions.

Các tùy chọn có sẵn

Specify duty point, electrical supply, control signal, curb, damper, disconnect, coating, access, wind rating and monitoring.

Planning a Centrifugal Roof Exhaust Fan 2037 CFM specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.