Bộ lọc quạt tiếng ồn thấp
- Acoustically Treated Plenum
- Elastomeric Fan Isolation
- Radiused Air Inlet
- Variable EC Speed Control
Giới thiệu Sản phẩm
The low-noise fan filter unit combines a backward-curved EC fan, vibration-isolated motor support and an acoustically treated plenum. A radiused inlet guides air into the wheel, while the final filter forms the clean-air outlet. The housing arrangement is intended for occupied cleanroom work areas where access for service, acoustic performance and filtered airflow all affect equipment selection.
Các tính năng chính
A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.
The acoustic treatment is located within the upstream plenum rather than on the downstream filter face.
Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.
Các giải pháp cho ứng dụng của bạn
Noise control in an occupied cleanroom depends on the selected duty and the installed sound-transmission paths, not the fan label alone.
Các ứng dụng điển hình
Thông số kỹ thuật
Common reference configuration choices for a low-noise ceiling FFU.
| Ceiling-Format Options | Common nominal formats: 2 x 2 ft and 2 x 4 ft |
|---|---|
| Vận tốc mặt tham chiếu | Typical selection target: 0.45 m/s, with adjustable EC fan speed |
| Lắp ráp quạt | Backward-curved centrifugal EC fan |
| Acoustic Treatment | Acoustically treated upstream plenum, with lining outside the final-filter discharge path |
| Vibration Isolation | Elastomeric isolation between the fan assembly and housing |
| Air-Inlet Construction | Radiused inlet feeding the centrifugal fan |
| Supply-Voltage Option | Common option: 230 V AC |
| Speed-Control Options | Local adjustment or 0-10 V analogue input; network control with a compatible controller |
| Final-Filter Options | HEPA or ULPA panel with a matched frame and perimeter seal |
| Giữ bộ lọc | Gasket-compression frame with removable outlet access |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Các tùy chọn có sẵn
Acoustic Selection and Installation
Compare sound at the required duty
Include the airflow requirement, filter resistance and operator position when requesting a low-noise selection. Acoustic comparisons need the same operating point, weighting, microphone distance and installation conditions. A sound-power figure is not interchangeable with a sound-pressure reading in the room.
Choose the filter and controls together
The final-filter grade and resistance affect the fan speed needed for the duty. Specify the filter seal and service access with the unit. Remote speed controllers and network interfaces are configuration choices; the acoustic construction should also identify the liner facing, enclosure and cleaning compatibility.
Protect the installation and maintenance path
Match the unit to the ceiling opening, load-bearing supports and available overhead space. Keep the inlet clear and avoid rigid service connections that bridge the vibration isolation. Electrical installation must match the supplied motor rating. Isolate the power before servicing and protect the final-filter media during handling.
If ceiling depth is the main constraint, compare the low-profile fan filter unit. For selections driven by added system resistance, see the high-static-pressure fan filter unit.
Planning a Low-Noise Fan Filter Unit specification?
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Tiếng Anh
Tiếng Bồ Đào Nha, tiếng Bồ Đào Nha
Tiếng Tây Ban Nha, tiếng Tây Ban Nha
Tiếng Mã Lai
Tiếng Indonesia (tiếng Việt)
Tiếng Đức, tiếng Đức
Tiếng Thổ Nhĩ Kỳ, tiếng Thổ Nhĩ Kỳ
Tiếng Việt / tiếng ViệtHiện tại
Tiếng Pháp, tiếng Pháp
Tiếng Nga, tiếng Nga
Tiếng Ả Rập, tiếng Ả Rập
Tiếng Thái (tiếng Thái)
Tiếng Nhật
Tiếng Hàn / tiếng Hàn