상품 소개
The low-noise fan filter unit combines a backward-curved EC fan, vibration-isolated motor support and an acoustically treated plenum. A radiused inlet guides air into the wheel, while the final filter forms the clean-air outlet. The housing arrangement is intended for occupied cleanroom work areas where access for service, acoustic performance and filtered airflow all affect equipment selection.
주요 기능
A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.
The acoustic treatment is located within the upstream plenum rather than on the downstream filter face.
Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.
응용 프로그램 솔루션
Noise control in an occupied cleanroom depends on the selected duty and the installed sound-transmission paths, not the fan label alone.
일반적인 응용 프로그램
기술 매개변수
Common reference configuration choices for a low-noise ceiling FFU.
| Ceiling-Format Options | Common nominal formats: 2 x 2 ft and 2 x 4 ft |
|---|---|
| Reference Face Velocity | Typical selection target: 0.45 m/s, with adjustable EC fan speed |
| Fan Assembly | Backward-curved centrifugal EC fan |
| Acoustic Treatment | Acoustically treated upstream plenum, with lining outside the final-filter discharge path |
| Vibration Isolation | Elastomeric isolation between the fan assembly and housing |
| Air-Inlet Construction | Radiused inlet feeding the centrifugal fan |
| Supply-Voltage Option | Common option: 230 V AC |
| Speed-Control Options | Local adjustment or 0-10 V analogue input; network control with a compatible controller |
| Final-Filter Options | HEPA or ULPA panel with a matched frame and perimeter seal |
| Filter Retention | Gasket-compression frame with removable outlet access |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Acoustic Selection and Installation
Compare sound at the required duty
Include the airflow requirement, filter resistance and operator position when requesting a low-noise selection. Acoustic comparisons need the same operating point, weighting, microphone distance and installation conditions. A sound-power figure is not interchangeable with a sound-pressure reading in the room.
Choose the filter and controls together
The final-filter grade and resistance affect the fan speed needed for the duty. Specify the filter seal and service access with the unit. Remote speed controllers and network interfaces are configuration choices; the acoustic construction should also identify the liner facing, enclosure and cleaning compatibility.
Protect the installation and maintenance path
Match the unit to the ceiling opening, load-bearing supports and available overhead space. Keep the inlet clear and avoid rigid service connections that bridge the vibration isolation. Electrical installation must match the supplied motor rating. Isolate the power before servicing and protect the final-filter media during handling.
If ceiling depth is the main constraint, compare the low-profile fan filter unit. For selections driven by added system resistance, see the high-static-pressure fan filter unit.