STJH-HOT-WATER-REHEAT-COIL-2ROW-12IN

Hot-Water Reheat Coil Two-Row 1/2-Inch

A compact single-circuit reheat core for restoring supply temperature after central cooling and dehumidification.
  • Two-row terminal core
  • 1/2 in water tubes
  • Single circuit
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This two-row half-inch coil is the shallowest dedicated reheat option in the group. A single water circuit and compact face suit terminal branches that add sensible heat after the central cooling coil has removed moisture. Sine or waffle fin patterns can be selected to match heat-transfer and air-resistance targets, while the two-row core supports fast control response at modest output.

Ana Özellikler

Post-dehumidification trim

The coil raises dry-bulb supply temperature without adding moisture after central cooling.

Compact terminal fit

Two rows limit section depth in local ducts and small reheat boxes.

Simple hydraulic control

A single circuit suits small flows and straightforward modulating-valve arrangements.

Teknik parametreler

Tube Rows2
Tube Outside Diameter1/2 in
Water CircuitSingle
Fin PatternSine or waffle
Fin MaterialAluminum by selection
Tube MaterialCopper by standard service
FluidHot water
CasingSelected for duct environment
Primary DutyTerminal post-cooling reheat
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For cleanroom terminal reheat, laboratory supply branches and humidity-control systems downstream of central dehumidification.

Solutions for Your Application

The reheat valve overshoots room temperature because coil water volume is very small.Use a properly sized modulating valve and tune control response for the shallow single-circuit core.
Reheat capacity is insufficient at minimum hot-water temperature.Rate the two-row coil at the actual flow and entering conditions and select a deeper model where necessary.

Mevcut Seçenekler

Confirm face size, airflow, reheat load, water temperatures, fin pattern, connection side, valve arrangement and casing material.

Planning a Hot-Water Reheat Coil Two-Row 1/2-Inch specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.