Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Cleanroom HVAC Systems / Hot-Water Reheat Coil Two-Row 1/2-Inch
STJH-HOT-WATER-REHEAT-COIL-2ROW-12IN

Hot-Water Reheat Coil Two-Row 1/2-Inch

A compact single-circuit reheat core for restoring supply temperature after central cooling and dehumidification.
  • Two-row terminal core
  • 1/2 in water tubes
  • Single circuit
Solicite un presupuesto. Browse productos

Introducción del producto

This two-row half-inch coil is the shallowest dedicated reheat option in the group. A single water circuit and compact face suit terminal branches that add sensible heat after the central cooling coil has removed moisture. Sine or waffle fin patterns can be selected to match heat-transfer and air-resistance targets, while the two-row core supports fast control response at modest output.

Características clave

Post-dehumidification trim

The coil raises dry-bulb supply temperature without adding moisture after central cooling.

Compact terminal fit

Two rows limit section depth in local ducts and small reheat boxes.

Simple hydraulic control

A single circuit suits small flows and straightforward modulating-valve arrangements.

Parámetros técnicos

Tube Rows2
Tube Outside Diameter1/2 in
Water CircuitSingle
Fin PatternSine or waffle
Fin MaterialAluminum by selection
Tube MaterialCopper by standard service
FluidHot water
CasingSelected for duct environment
Primary DutyTerminal post-cooling reheat
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

For cleanroom terminal reheat, laboratory supply branches and humidity-control systems downstream of central dehumidification.

Solutions for Your Application

The reheat valve overshoots room temperature because coil water volume is very small.Use a properly sized modulating valve and tune control response for the shallow single-circuit core.
Reheat capacity is insufficient at minimum hot-water temperature.Rate the two-row coil at the actual flow and entering conditions and select a deeper model where necessary.

Opciones disponibles

Confirm face size, airflow, reheat load, water temperatures, fin pattern, connection side, valve arrangement and casing material.

Planning a Hot-Water Reheat Coil Two-Row 1/2-Inch specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto