Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Ekipmanları / Single-Person Cleanroom Air Shower Double-Sided Floorless
STJH-DOUBLE-SIDED-SINGLE-PERSON-AIR-SHOWER-FLOORLESS

Single-Person Cleanroom Air Shower Double-Sided Floorless

A flush-entry, floorless one-person chamber with bilateral wall jets and ceiling nozzles.
  • No integral floor
  • 18 wall and ceiling nozzles
  • 770 mm clear width
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This 1100 x 1000 x 2100 mm chamber uses the facility's finished floor rather than an integral base. Its 770 x 1000 x 1935 mm passage is treated by 18 nozzles across both side walls and the ceiling. The floorless threshold is the defining installation difference within the three double-sided single-person variants.

Ana Özellikler

Flush personnel threshold

The facility floor continues through the air shower, avoiding a raised step at either door.

Three-direction coverage

Eight nozzles on each wall and two overhead jets surround a single gowned operator.

Interlocked transition

The two-door sequence separates the non-clean and clean sides during the shower cycle.

Teknik parametreler

External Dimensions1100 x 1000 x 2100 mm
Clear Passage770 x 1000 x 1935 mm
OccupancyOne person
Nozzle Count18
Nozzle Distribution8 per side wall plus 2 ceiling
FloorNone; facility finished floor continues through
DoorsManual aluminium doors
InterlockTwo-door interlock
Power SupplyAC 200 V, three phase, 50/60 Hz
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For new cleanroom construction with a continuous finished floor, wheeled-access preference or strict trip-hazard control. The floor interface must be sealed and remain cleanable through the chamber.

Solutions for Your Application

An integral base would create an unwanted step in the personnel route.Install the floorless cabinet over the completed level floor and seal its perimeter.
One-sided jets leave the far side of garments untreated.Use the bilateral eight-plus-eight wall pattern with two additional ceiling nozzles.

Mevcut Seçenekler

Confirm door handing, finished-floor seal, controls, timer, lighting and access integration. The surrounding floor must support cleaning beneath both thresholds.

Planning a Single-Person Cleanroom Air Shower Double-Sided Floorless specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat