Ana Sayfa / Ürünler / Temiz Oda Ekipmanları / Clean Ward Supply Ceiling 1355 × 1355 mm
STJH-CLEAN-WARD-SUPPLY-CEILING-1355X1355

Clean Ward Supply Ceiling 1355 × 1355 mm

A compact H14-filtered ceiling outlet for localized clean-air protection above one patient or treatment position.
  • 1355 x 1355 mm compact field
  • 1660 m³/h design airflow
  • Polyester-cloth air outlet
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The 1355 mm square ward ceiling supplies a cited 1660 m³/h through a polyester-cloth outlet, creating a localized low-turbulence air zone over one bed or treatment position. Its compact footprint minimizes interference with luminaires, medical rails and ceiling services. The model is intended for targeted patient protection rather than full-room unidirectional coverage.

Ana Özellikler

Single-position protection

The compact field concentrates clean supply air over one patient or clinical work location.

Soft air distribution

A polyester-cloth outlet spreads the H14-filtered air with low turbulence at the occupied zone.

Service-friendly footprint

The smaller square leaves more ceiling area for lights, rails and medical utilities.

Teknik parametreler

Outlet Field1355 x 1355 mm
Clean Airflow1660 m³/h
Final Filter ClassH14
Outlet MaterialPolyester cloth
Flow CharacterLow-turbulence downward supply
CoverageOne patient or treatment position
InstallationCeiling integrated
Plenum ConstructionProject-selected cleanroom material
Hava akışı kontrolüMatched to ward pressure and ventilation plan
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For a single protective-environment bed, isolation-room care point or clinical treatment station needing localized H14-filtered supply air.

Solutions for Your Application

Treating the entire room to the same cleanliness level uses unnecessary airflow.Concentrate the 1355 mm clean-air field above the occupied care position.
A rigid high-velocity outlet creates drafts around the patient.Use the polyester distribution cloth to deliver a broad low-turbulence downward flow.

Mevcut Seçenekler

Configure plenum material, filter access, suspension, outlet cloth, airflow monitoring and ceiling-service coordination. Final duty is balanced with room pressure requirements.

Planning a Clean Ward Supply Ceiling 1355 × 1355 mm specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim