Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Cleanroom HVAC Systems / Centrifugal Cleanroom Exhaust-Air Fan Unit 3322 CFM
STJH-CENTRIFUGAL-CLEANROOM-EXHAUST-FAN-3322CFM

Centrifugal Cleanroom Exhaust-Air Fan Unit 3322 CFM

A large direct-drive square inline fan for 1808-3322 CFM exhaust and return duty, with family pressure capability up to 1.75 in. wg.
  • 1808-3322 CFM airflow
  • Direct-drive large impeller
  • Up to 1.75 in. wg family static
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The 3322 CFM version uses a larger casing, impeller and motor assembly than the two lower-flow exhaust models. It targets high-volume return and general exhaust branches where an inline footprint is preferred, with published family capability extending to 1.75 inches water gauge depending on the selected operating point.

Ana Özellikler

High-volume branch duty

The airflow range covers major return or exhaust branches rather than one local room outlet.

Compact high-capacity form

A square inline enclosure reduces the transition length normally associated with a conventional centrifugal scroll.

Belt-free power train

The motor couples directly to the wheel, eliminating belt guards, pulleys and tension checks.

Teknik parametreler

Airflow Range1808-3322 CFM
Maximum Family StaticUp to 1.75 in. wg
Fan TypeInline centrifugal
DriveDirect
Impeller ScaleLarge high-volume wheel
CasingSquare duct-mounted enclosure
OrientationHorizontal or vertical by arrangement
ConnectionsRectangular flanged inlet and outlet
DutyHigh-volume exhaust or return air
Customization (Özelleşme)Motor selection, controls, casing finish and duct interfaces can be tailored to the intended application and operating environment.

Applications

Large cleanroom exhaust headers, central return-air branches, production support ventilation and high-volume makeup-air transfer.

Solutions for Your Application

Several small fans create uneven flow and too many service points on one main branch.Use one correctly selected 3322 CFM unit and balance downstream branches at their dampers.
Available static pressure is uncertain once filters and silencers are added.Plot the complete system resistance and select the fan point within the family curve rather than relying on free-air volume.

Mevcut Seçenekler

Variable speed control, motorized damper, coated steel construction, acoustic treatment, vibration mounts and access switches are available.

Planning a Centrifugal Cleanroom Exhaust-Air Fan Unit 3322 CFM specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim