The smallest crossflow plate core for recovering sensible heat while keeping supply and exhaust physically separated.
  • 500 mm plate size
  • 250-1000 mm module width
  • 1.9-6.0 mm spacing options
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This compact H2 plate core uses a 500 mm plate size and module widths from 250-1000 mm. Aluminum crossflow passages are available with 1.9-6.0 mm spacing, letting resistance and fouling tolerance be balanced for small clean AHUs. Depending on seal selection, the family supports 90-240 C maximum temperature; the chosen seal and leakage requirement must match the actual air streams.

Ana Özellikler

Separated airflow paths

Alternating aluminum channels exchange sensible heat without intentional mixing or a rotating matrix.

Compact core geometry

The smallest plate diagonal fits local and small clean-air units.

Selectable channel spacing

Wider gaps improve fouling tolerance while tighter gaps increase surface density.

Teknik parametreler

Plate Size500 mm
Module Width250-1000 mm
Plate Spacing1.9-6.0 mm options
Plate MaterialAluminum
Flow ArrangementCrossflow
Maximum Temperature90-240 C depending on seal
Moving PartsNone
Recovery TypePrimarily sensible
Primary DutySmall separated-stream heat recovery
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

For small clean AHUs and laboratory ventilation systems where supply and exhaust should remain physically separated.

Solutions for Your Application

Condensate freezes in the small exhaust passages during winter operation.Apply bypass, preheat or airflow control based on exhaust condition and frost calculation.
Narrow plate spacing fouls rapidly in the actual exhaust stream.Select a wider passage, provide filtration and preserve access for cleaning and drainage.

Mevcut Seçenekler

Confirm airflows, temperatures, plate spacing, module width, seal material, bypass, condensate pan, filtration and access.

Planning a Air-to-Air Plate Heat Recovery Unit 500 mm specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim