Inicio / Productos / Cleanroom HVAC Systems / Direct-Expansion Cooling Coil Six-Row
STJH-DIRECT-EXPANSION-COOLING-COIL-6ROW

Direct-Expansion Cooling Coil Six-Row

A medium-depth DX evaporator with more surface and circuits than the four-row version for greater latent capacity.
  • Six-row evaporator core
  • 11 in casing depth
  • Typically 8-10 fins per inch
Solicite un presupuesto. Browse productos

Introducción del producto

The six-row DX construction increases published casing depth to 11 in and commonly uses 8-10 fins per inch. Additional tube surface and refrigerant circuits provide more total and latent capacity than the four-row core while retaining counterflow operation. It suits medium cleanroom air handlers that need deeper dehumidification without the full 13.5 in envelope and pressure burden of the eight-row model.

Características clave

Expanded latent surface

Two additional tube rows increase cold-surface contact for moisture removal.

Multi-circuit distribution

More circuits divide refrigerant across the face for stable loading at medium capacity.

Balanced installation depth

The 11 in casing sits between the compact and high-latent DX configurations.

Parámetros técnicos

Tube Rows6
Casing Depth11 in
Fin DensityTypically 8-10 fins per inch
Tube MaterialCopper for compatible refrigerant
CircuitingCounterflow DX
Fin MaterialAluminum by standard duty
Face VelocitySelected for wet-coil performance
Condensate ControlFull drain pan below core
Primary DutyMedium total and latent cooling
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Applications

For pharmaceutical and electronics cleanroom AHUs requiring medium DX cooling and more dehumidification than a shallow evaporator provides.

Solutions for Your Application

Refrigerant distribution leaves outer circuits starved at part load.Select distributor, circuit length and valve turndown for the full expected capacity range.
Close fins foul quickly in a high-outdoor-air system.Use effective upstream filtration and preserve access for cleaning both faces of the six-row core.

Opciones disponibles

Specify refrigerant, circuit count, distributor, face dimensions, fin density, tube wall, coating, casing and condensate accessories.

Planning a Direct-Expansion Cooling Coil Six-Row specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.