A medium-depth DX evaporator with more surface and circuits than the four-row version for greater latent capacity.
  • Six-row evaporator core
  • 11 in casing depth
  • Typically 8-10 fins per inch
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The six-row DX construction increases published casing depth to 11 in and commonly uses 8-10 fins per inch. Additional tube surface and refrigerant circuits provide more total and latent capacity than the four-row core while retaining counterflow operation. It suits medium cleanroom air handlers that need deeper dehumidification without the full 13.5 in envelope and pressure burden of the eight-row model.

الخصائص الرئيسية

Expanded latent surface

Two additional tube rows increase cold-surface contact for moisture removal.

Multi-circuit distribution

More circuits divide refrigerant across the face for stable loading at medium capacity.

Balanced installation depth

The 11 in casing sits between the compact and high-latent DX configurations.

المعلمات الفنية

Tube Rows6
Casing Depth11 in
Fin DensityTypically 8-10 fins per inch
Tube MaterialCopper for compatible refrigerant
CircuitingCounterflow DX
Fin MaterialAluminum by standard duty
Face VelocitySelected for wet-coil performance
Condensate ControlFull drain pan below core
Primary DutyMedium total and latent cooling
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For pharmaceutical and electronics cleanroom AHUs requiring medium DX cooling and more dehumidification than a shallow evaporator provides.

Solutions for Your Application

Refrigerant distribution leaves outer circuits starved at part load.Select distributor, circuit length and valve turndown for the full expected capacity range.
Close fins foul quickly in a high-outdoor-air system.Use effective upstream filtration and preserve access for cleaning both faces of the six-row core.

الخيارات المتاحة

Specify refrigerant, circuit count, distributor, face dimensions, fin density, tube wall, coating, casing and condensate accessories.

Planning a Direct-Expansion Cooling Coil Six-Row specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا