Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
STJH-OPERATING-ROOM-LAMINAR-CEILING-2575

Operating Room Laminar Flow Ceiling 2575 × 2575 mm

A compact recirculating surgical canopy delivering a defined H14-filtered clean-air field for procedural rooms.
  • 2575 x 2575 mm airflow field
  • 5970 m³/h clean-air supply
  • 3980 m³/h recirculated air
Запрос котировки Просмотреть продукты

Введение продукции

The 2575 mm square canopy is sized for operating or procedure rooms where the protected zone must remain compact. At the cited design point it supplies 5970 m³/h of clean air, including 3980 m³/h of recirculation. The smaller field reduces the ceiling footprint while retaining a downward filtered airflow zone over the selected surgical area.

Основные характеристики

Compact ceiling footprint

The 2.575 m square field fits procedural rooms where lights and services constrain available ceiling area.

Recirculation contribution

A large share of the design airflow is recirculated locally to reduce the outside-air burden.

Terminal H14 filtration

Final filtration at the canopy supports clean downward air delivery above the clinical zone.

Технические параметры

Airflow Field2575 x 2575 mm
Clean Airflow5970 m³/h
Recirculation Airflow3980 m³/h
Final Filter ClassH14
Air DistributionLow-turbulence downward flow
InstallationCeiling-integrated canopy
Typical ZoneCompact operating or procedure area
Ceiling CoordinationLights, pendants and services by layout
Управление воздушным потокомMatched to operating-room HVAC design
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

For compact operating theatres and procedure rooms needing a defined ultra-clean field above the table. Air balance, light placement and peripheral return locations are coordinated with the room HVAC design.

Solutions for Your Application

A larger canopy conflicts with ceiling-mounted clinical equipment in a small room.Use the 2575 mm field and coordinate its perimeter around lights and service pendants.
Supplying the entire clean-air volume as outside air increases plant load.Use the cited recirculation contribution while maintaining the required room ventilation balance.

Доступные варианты

Configure filter-module layout, recirculation connection, outlet fabric, lighting interface and service cut-outs. Final airflow follows the clinical risk and HVAC calculations.

Planning a Operating Room Laminar Flow Ceiling 2575 × 2575 mm specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты