Electrical function through the body
The conductive material is distributed through the wearing section, rather than relying solely on a temporary treatment applied after the floor has been laid.
Carbon-encapsulated granules form the electrical network throughout this 2 mm homogeneous vinyl sheet. The configuration targets the conductive resistance band of 10^4 to 10^6 ohms using the relevant floor test method, and it is installed as a grounded system. Its roll format is useful for wide electronics bays where the floor should remain continuous around workstations and mobile production equipment.
The conductive material is distributed through the wearing section, rather than relying solely on a temporary treatment applied after the floor has been laid.
Joined sheets provide a cleanable field around fixed benches. Plan the joints before installation so narrow strips do not create unnecessary maintenance edges.
The conductive band serves equipment areas with a defined low-resistance floor requirement. It should not be substituted automatically for a higher-resistance dissipative specification.
| Sheet Construction | Homogeneous conductive PVC |
|---|---|
| Nominal Thickness | 2 mm |
| Electrical Network | Carbon-encapsulated granules |
| Selection Resistance Range | 10^4–10^6 Ω |
| Product Format | Continuous roll sheet |
| Seams | Heat welded |
| Backing Function | Conductive backing |
| Installation System | Grounded adhesive-bonded floor |
| Finish Care | Compatible ESD cleaning procedure |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Suitable for electronics production bays and technical clinical support areas specifying conductive sheet flooring. Resistance measurements must use the stated method and conditions because different tests describe different paths through the installation. Personnel protection and device protection are considered together when selecting footwear and the earthing arrangement.
Compare the actual resistance range and test method, not only the word antistatic on a product description.
Develop the roll layout around fixed equipment footprints and form clean, accessible seams at planned locations.
Choose the sheet colour and matching weld material, then define the conductive adhesive and earth connection arrangement. Keep repair pieces compatible with the same electrical construction so later local repairs preserve the intended network.
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.