A deep-plenum FFU for cleanroom duties with added air-path resistance, combining a backward-curved EC fan, reinforced casing and pressure-test access.
  • Deep Reinforced Pressure Plenum
  • Backward-Curved EC Impeller
  • Accessible Pressure-Test Port
  • Variable-Speed Fan Adjustment
Запрос котировки Просмотреть продукты

Введение продукции

The high-static-pressure fan filter unit combines a backward-curved EC impeller, deep inlet arrangement and reinforced plenum. Formed ribs and corner reinforcement support the casing, while a capped test connection provides access for pressure measurements. The unit is intended for cleanroom selections in which inlet losses or final-filter resistance are important parts of the airflow duty. Pressure capability is evaluated at the required flow, not from the motor size or housing depth alone.

Основные характеристики

A deep inlet arrangement provides space around the backward-curved centrifugal impeller.

Formed ribs and reinforced corners limit casing deflection when the plenum operates at elevated static pressure.

A capped pressure port provides a repeatable connection point for commissioning and maintenance measurements.

Variable EC fan speed provides an adjustment range for balancing the selected fan and filter combination.

Решения для вашего приложения

A high-resistance duty needs an airflow-and-pressure selection for the complete installation rather than a maximum-pressure figure in isolation.

An added duct collar changes the inlet condition assumed for an open-plenum selection.Include the actual duct and fitting losses when selecting the operating point.
Available airflow can fall as final-filter resistance increases.Check the loaded-filter duty against the fan curve and permitted operating range, rather than assuming the controller can always restore flow.
Higher internal pressure places additional demand on casing joints and filter seals.Pair the reinforced housing with the specified filter interface and inspect the assembled seals during commissioning.
A pressure reading alone cannot identify every cause of low airflow.Record inlet pressure, filter differential pressure and delivered airflow together to separate air-supply, filter and fan-setting issues.

Типичные приложения

Duct-connected cleanroom ceiling systemsTerminal ULPA filtrationRecirculation systems with added inlet resistanceHigh-resistance clean-air modulesProcess areas with variable air-path resistance

Технические параметры

Common reference configuration choices for a pressure-duty ceiling FFU.

Module-Format OptionCommon nominal format: 2 x 4 ft
Fan and DriveBackward-curved centrifugal impeller with variable-speed EC drive
Pressure-Plenum ConstructionDeep reinforced casing around the fan and final-filter support
Скорость лица ссылкиTypical selection target: 0.45 m/s through the final-filter face
Air-Inlet OptionsOpen-plenum inlet or duct-collar connection
Pressure-Test ConnectionCapped static-pressure tapping on the fan plenum
Электрический вариантCommon supply option: 230 V AC
Control-Interface OptionsLocal speed setting, 0-10 V analogue reference or compatible network controller
Final-Filter ConfigurationHEPA or ULPA panel selected with the fan duty
Perimeter-Seal OptionsDry-gasket compression or matched gel-seal construction
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Duct collar or open top intakeHigh-pressure EC motor and impeller selectionFilter differential-pressure portDeep-pack HEPA or ULPA filter with gel interface

Pressure-Duty Selection and Installation

Define the full resistance path

For a quotation, state the required airflow and external losses at that airflow, including inlet ductwork, fittings and any prefilter. List the final-filter resistance separately so that internal filter pressure drop is not counted twice. The selected fan curve must cover both the clean-filter duty and the intended loaded-filter limit.

Match the inlet and control arrangement

Choose an open intake or a dimensioned duct collar, the final-filter grade, and the gasket or gel-seal construction. An EC motor does not by itself establish constant-airflow operation. Where an upstream air-control device is used, select compatible control behaviour rather than allowing two independent controllers to regulate the same airflow.

Install for measurement and service

Allow access to the test connection, motor controls and filter removal path. Use the specified ceiling support layout and electrical rating, and measure delivered airflow as well as pressure during balancing. Disconnect power before filter or fan maintenance.

A standard fan filter unit may suit a lower-resistance ceiling duty. If the main requirement is increased total volume across a broad outlet, compare the high-airflow fan filter unit.

Planning a High-Static-Pressure Fan Filter Unit specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.