A self-supporting one-person air shower with an integral floor case and 18-nozzle surround coverage.
  • Integral floor case
  • 2150 mm overall height
  • 18-nozzle surround pattern
Solicite um orçamento. Browse produtos

Introdução do produto

This version adds an integral floor case beneath the same 770 x 1000 x 1935 mm clear passage used by the floorless model. The base increases overall height to 2150 mm and creates a defined factory-built walking surface. Eighteen nozzles cover both walls and the ceiling, while interlocked manual aluminium doors control movement through the chamber.

Características-chave

Self-contained base

The floor case provides a known chamber surface where the existing facility floor is unsuitable.

Bilateral garment cleaning

Opposing side banks reduce the need for the operator to turn during the cycle.

Defined installation datum

The integral case supplies a level base for the cabinet and both door thresholds.

Parâmetros técnicos

External Dimensions1100 x 1000 x 2150 mm
Clear Opening770 x 1000 x 1935 mm
Rated UsersSingle person
Air Jets18 total
Jet LayoutBoth side walls and ceiling
BaseIntegral floor case
Door MaterialAluminium
Door SafetyInterlocked two-door passage
Electrical SupplyAC 200 V, three phase, 50/60 Hz
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

Suited to finished facilities, retrofit entrances and locations where a factory-defined chamber floor simplifies placement. Account for the raised case when coordinating adjacent ramps or floor transitions.

Solutions for Your Application

The existing floor cannot form a sealed cleanable chamber base.Use the integral floor case to isolate the walking surface from the underlying finish.
A raised threshold may impede carts or mobility access.Reserve the floor-case model for personnel routes or provide a transition designed for the installed base height.

Opções disponíveis

Select threshold treatment, door swing, cabinet finish, access controls and cycle settings. A low transition or ramp can be configured for the surrounding floor level.

Planning a Single-Person Cleanroom Air Shower Double-Sided Floor-Case specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato