Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Cleanroom HVAC Systems / Direct Steam Injection Humidifier 1-1/4-Inch Inlet
STJH-DIRECT-STEAM-INJECTION-HUMIDIFIER-114INLET

Direct Steam Injection Humidifier 1-1/4-Inch Inlet

A medium stainless separator body and manifold package for pharmaceutical and healthcare supply ducts.
  • 1-1/4 in steam inlet
  • 230 mm-class separator body
  • 1-1/4 in condensate drain
Solicite um orçamento. Browse produtos

Introdução do produto

The medium direct-injection unit increases the steam inlet to 1-1/4 in NPT and uses a larger internal separation chamber with a 230 mm-class body dimension. A matching 1-1/4 in drain connection handles separated condensate before dry steam enters the manifold. It serves greater duct humidity loads than the compact model while retaining corrosion-resistant 300-series stainless wetted construction.

Características-chave

Larger separation chamber

The medium body provides more space to remove entrained moisture from the plant-steam stream.

Matched condensate outlet

A full 1-1/4 in drain connection supports reliable removal from the separator.

Clean-service stainless construction

300-series wetted parts suit pharmaceutical and healthcare air systems.

Parâmetros técnicos

Steam Inlet1-1/4 in NPT
Drain Connection1-1/4 in NPT
Body Cross-Section230 mm N-dimension class
Wetted Material300-series stainless steel
Steam SourceConditioned plant steam
SeparationIntegral internal moisture separation
ControlModulating valve and actuator
DistributionDuct manifold sized to width and output
Primary DutyMedium clean-air humidification
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For medium pharmaceutical, hospital and controlled-production supply ducts with a suitable conditioned steam source.

Solutions for Your Application

A poorly trapped separator backs condensate into the steam manifold.Provide adequate drain head, correctly sized trap and gravity routing under all operating pressures.
The manifold is placed too close to a filter or elbow for complete absorption.Calculate non-wetting distance and reserve straight duct before downstream obstructions.

Opções disponíveis

Confirm steam pressure and quality, capacity, body orientation, valve, actuator, manifold count, trap, drain and duct absorption length.

Planning a Direct Steam Injection Humidifier 1-1/4-Inch Inlet specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato