The shallowest selected cooling core for moderate sensible duty and lower air-side pressure loss.
  • Four-row shallow core
  • 5/8 in copper tubes
  • Up to 250 psig family duty
Solicite um orçamento. Browse produtos

Introdução do produto

The four-row chilled-water core provides the shortest casing depth in this cooling-coil trio. Five-eighth-inch copper tubes are available with 0.020-0.049 in wall options and the referenced family supports up to 250 psig operating pressure. With fewer rows than the six- and eight-row models, it favors lower air resistance and modest condensate duty over deep dehumidification.

Características-chave

Lower air-side burden

The shorter tube bank reduces resistance compared with deeper latent-cooling coils.

Selectable tube wall

Copper wall options allow the coil to be matched to pressure, corrosion allowance and service life.

Compact condensate section

A shallower wet core requires less AHU depth while still providing planned drain-pan coverage.

Parâmetros técnicos

Tube Rows4
Tube Outside Diameter5/8 in
Tube Wall Options0.020-0.049 in
Tube MaterialCopper
Maximum Operating Pressure250 psig family basis
CasingGalvanized or stainless by selection
FluidChilled water
Condensate RequirementDrain pan below wet coil
Primary DutyModerate sensible cooling
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For clean AHUs with moderate sensible cooling load, limited section depth or a requirement to minimize fan pressure consumption.

Solutions for Your Application

The four-row core cannot reach the specified dew point during peak latent load.Rate leaving-air temperature and moisture removal; choose six or eight rows where deeper cooling is necessary.
Condensate carries downstream at excessive face velocity.Size the face area for wet-coil velocity and provide a correctly sloped drain pan and eliminator where required.

Opções disponíveis

Specify capacity, water temperatures, tube wall, fin spacing, circuiting, casing, coating, drain pan and connection orientation.

Planning a Chilled-Water Cooling Coil Four-Row 5/8-Inch specification?