Главная / Продукция / Cleanroom HVAC Systems / Chilled-Water Cooling Coil Four-Row 5/8-Inch
STJH-CHILLED-WATER-COOLING-COIL-4ROW-58IN

Chilled-Water Cooling Coil Four-Row 5/8-Inch

The shallowest selected cooling core for moderate sensible duty and lower air-side pressure loss.
  • Four-row shallow core
  • 5/8 in copper tubes
  • Up to 250 psig family duty
Запрос котировки Просмотреть продукты

Введение продукции

The four-row chilled-water core provides the shortest casing depth in this cooling-coil trio. Five-eighth-inch copper tubes are available with 0.020-0.049 in wall options and the referenced family supports up to 250 psig operating pressure. With fewer rows than the six- and eight-row models, it favors lower air resistance and modest condensate duty over deep dehumidification.

Основные характеристики

Lower air-side burden

The shorter tube bank reduces resistance compared with deeper latent-cooling coils.

Selectable tube wall

Copper wall options allow the coil to be matched to pressure, corrosion allowance and service life.

Compact condensate section

A shallower wet core requires less AHU depth while still providing planned drain-pan coverage.

Технические параметры

Tube Rows4
Tube Outside Diameter5/8 in
Tube Wall Options0.020-0.049 in
Tube MaterialCopper
Maximum Operating Pressure250 psig family basis
CasingGalvanized or stainless by selection
FluidChilled water
Condensate RequirementDrain pan below wet coil
Primary DutyModerate sensible cooling
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Applications

For clean AHUs with moderate sensible cooling load, limited section depth or a requirement to minimize fan pressure consumption.

Solutions for Your Application

The four-row core cannot reach the specified dew point during peak latent load.Rate leaving-air temperature and moisture removal; choose six or eight rows where deeper cooling is necessary.
Condensate carries downstream at excessive face velocity.Size the face area for wet-coil velocity and provide a correctly sloped drain pan and eliminator where required.

Доступные варианты

Specify capacity, water temperatures, tube wall, fin spacing, circuiting, casing, coating, drain pan and connection orientation.

Planning a Chilled-Water Cooling Coil Four-Row 5/8-Inch specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.