Laman Utama / Produk / Peralatan Bilik Bersih / High-Airflow Fan Filter Unit
FFU dan Peralatan Penulenan Udara Terminal

Unit Penapis Kipas Aliran Udara Tinggi

A large-format FFU with two EC blowers and a broad final-filter face, bringing a twin-fan clean-air supply assembly into one reinforced ceiling housing.
  • Twin EC Blower Arrangement
  • Large-Format Ceiling Housing
  • Broad Final-Filter Face
  • Common Control Enclosure
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The high-airflow fan filter unit combines two EC blowers with a broad final-filter face in a reinforced ceiling housing. A central enclosure serves the twin-fan assembly, and the wide filter frame provides the outlet area for clean-air distribution. The large-format arrangement is intended for clean-air zones in which total delivered volume and the spatial distribution of that air must be considered together.

Ciri-ciri Utama

Two EC blowers are incorporated into a single large-format ceiling module.

The final-filter face extends beneath both blower positions.

A central enclosure brings the two blower connections together above the outlet assembly.

A reinforced perimeter supports the wide filter and diffuser assembly.

Penyelesaian untuk permohonan anda

A high total airflow figure is only useful when the outlet pattern, control zoning and service requirements suit the work area.

One large module and several smaller modules create different control and maintenance layouts.Compare independent zones, electrical connections, ceiling coverage and replacement access before choosing the footprint.
A total volume figure does not show whether air reaches the far edges of a wide outlet.Define a multi-point velocity check across the effective filter face, including the areas beneath each blower.
A wide filter assembly needs space for removal as well as installation.Allow a clear service route and a safe lifting method for the complete filter and diffuser assembly.
Equal motor speeds do not by themselves establish equal airflow from the two fan zones.Evaluate the installed outlet pattern and use the specified control adjustment method when balancing the module.

Permohonan yang biasa

High-coverage semiconductor clean zonesLarge laminar-flow work areasBattery and precision-component productionCleanrooms with limited ceiling-module positionsHigh-air-change process rooms

Parameter teknikal

Common reference configuration choices for a large-format, twin-blower FFU.

Blower ArrangementTwo EC blowers within a shared ceiling housing
Large-Format ModuleCommon nominal format: 4 x 4 ft
Metric Housing FootprintTypical metric-family option: 1175 x 1175 mm
Halaju muka rujukanTypical selection target: 0.45 m/s over the final-filter face
Pembinaan perumahanReinforced metal casing with a broad final-filter support frame
Final-Filter ChoicesLarge-face HEPA or ULPA panel configuration
Supply-Voltage OptionCommon option: 230 V AC
Control AssemblyCommon electrical enclosure serving the twin-blower arrangement
Speed-Reference OptionsLocal adjustment or 0-10 V analogue reference; remote grouping with a compatible controller
Filter-Seal ConstructionPerimeter gasket compressed against the final-filter frame
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Alternative large-format housing layoutsHEPA or ULPA final-filter selectionLocal speed adjustmentCompatible remote or group-control configuration

Air-Volume Selection and Installation

Size by delivered volume and usable outlet area

State the required total airflow in m³/h, the external resistance and the final-filter configuration. Use the effective open filter face when relating volume to average velocity; nominal housing area is not the same as usable outlet area. Room air-change calculations also require the room volume and the complete supply-and-return layout.

Choose the footprint and service arrangement

Provide the ceiling opening, supporting grid, available headroom and the route for lifting and replacing the filter assembly. Select the filter grade and sealing arrangement with the unit. Local adjustment and remote control are separate configuration choices; the supplied control system determines how the two blowers are adjusted and monitored.

Balance both fan zones

During commissioning, check total delivery and the velocity pattern at several positions beneath the filter rather than only at the centre. Match the circuit to the supplied electrical rating, secure the wide housing on its specified supports and isolate power before servicing either blower.

For resistance-led selections, compare the high-static-pressure fan filter unit. For smaller independently controlled ceiling zones, review the EC fan filter unit.

Planning a High-Airflow Fan Filter Unit specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.