An open-floor cart transfer cabinet with internal 375 CFM HEPA recirculation for loads that need active particle control.
  • 375 CFM internal recirculation
  • 99.99% HEPA filtration
  • Open-floor cart access
견적 요청 제품 찾아보기

상품 소개

This filtered floor-standing model retains the threshold-free cart path but adds a motorized HEPA unit inside the cabinet. Air recirculates at 375 CFM through perforations in the inner side panels and a 99.99% HEPA stage. It serves larger parts and wheeled loads that need more protection than the passive standard cabinet, while remaining distinct from a high-velocity cargo air shower.

주요 기능

Filtered cart transfer

Active recirculation helps control airborne particles around wheeled loads during the closed-door interval.

Side-return airflow path

Perforated inner panels provide distributed return openings without adding a raised transfer floor.

Dedicated 120 V fan unit

The listed 0.83 A motorized filter package can be planned as a discrete cleanroom utility load.

기술 매개변수

MountingFloor-standing at the room boundary
Transfer FloorNo integrated floor
Recirculation Airflow375 CFM at 110 ft/min
Final Filter99.99% HEPA
Air ReturnPerforated stainless inner side panels
Fan Electrical120 V, 60 Hz, 0.83 A
ConstructionFormed and stitch-welded type 304 #4 stainless steel
Door HardwareCompression latches, continuous hinges and closed-cell gaskets
InterlockMechanical option with type 316 stainless handles
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For carts, large component kits and production fixtures entering cleanrooms where the transfer enclosure should actively recirculate filtered air. Confirm that 375 CFM is appropriate for the selected chamber size and load blockage, and preserve service clearance for fan and filter replacement.

Solutions for Your Application

Passive cart transfer allows loose airborne particles to remain around the load before the clean-side door opens.Use the internal HEPA recirculation unit during a controlled closed-door dwell period to reduce the particle burden in the chamber air.
A filtered chamber may become ineffective when carts block the side returns.Size the clear width around the largest cart so both perforated return panels remain open and accessible for cleaning.