STJH-FLOOR-STANDING-PASS-BOX-HEPA-375

Floor-Standing HEPA Pass Box 375 CFM

An open-floor cart transfer cabinet with internal 375 CFM HEPA recirculation for loads that need active particle control.
  • 375 CFM internal recirculation
  • 99.99% HEPA filtration
  • Open-floor cart access
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This filtered floor-standing model retains the threshold-free cart path but adds a motorized HEPA unit inside the cabinet. Air recirculates at 375 CFM through perforations in the inner side panels and a 99.99% HEPA stage. It serves larger parts and wheeled loads that need more protection than the passive standard cabinet, while remaining distinct from a high-velocity cargo air shower.

الخصائص الرئيسية

Filtered cart transfer

Active recirculation helps control airborne particles around wheeled loads during the closed-door interval.

Side-return airflow path

Perforated inner panels provide distributed return openings without adding a raised transfer floor.

Dedicated 120 V fan unit

The listed 0.83 A motorized filter package can be planned as a discrete cleanroom utility load.

المعلمات الفنية

MountingFloor-standing at the room boundary
Transfer FloorNo integrated floor
Recirculation Airflow375 CFM at 110 ft/min
Final Filter99.99% HEPA
Air ReturnPerforated stainless inner side panels
Fan Electrical120 V, 60 Hz, 0.83 A
ConstructionFormed and stitch-welded type 304 #4 stainless steel
Door HardwareCompression latches, continuous hinges and closed-cell gaskets
InterlockMechanical option with type 316 stainless handles
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For carts, large component kits and production fixtures entering cleanrooms where the transfer enclosure should actively recirculate filtered air. Confirm that 375 CFM is appropriate for the selected chamber size and load blockage, and preserve service clearance for fan and filter replacement.

Solutions for Your Application

Passive cart transfer allows loose airborne particles to remain around the load before the clean-side door opens.Use the internal HEPA recirculation unit during a controlled closed-door dwell period to reduce the particle burden in the chamber air.
A filtered chamber may become ineffective when carts block the side returns.Size the clear width around the largest cart so both perforated return panels remain open and accessible for cleaning.

الخيارات المتاحة

Define chamber dimensions, control sequence, interlock, door windows and mounting frames. Plan filter access, replacement route, alarm contacts and the closed-door recirculation interval as part of the operating procedure.

Planning a Floor-Standing HEPA Pass Box 375 CFM specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat