A three-blower stainless air shower tunnel for higher-throughput personnel entry to classified clean areas.
  • 136 in internal travel length
  • Three blower modules
  • Approximately four-person chamber
견적 요청 제품 찾아보기

상품 소개

At 144 in overall depth, this is the longest accepted explosion-resistant configuration. The 136 in internal path and three blower sections support approximately four occupants or a longer staged passage. Stainless construction, pneumatic access and the cited Class I, Division 2 basis distinguish it from general cleanroom tunnels; the Group C and D lighting basis must still be reconciled with the actual site classification.

주요 기능

Longest classified route

The 136 in chamber provides the greatest active travel and holding distance in this hazardous-location series.

Three-section air treatment

Separate blower zones distribute filtered jet coverage along the extended tunnel.

Higher personnel throughput

Approximate four-person occupancy reduces the number of cycles needed during coordinated entries.

기술 매개변수

Overall Size52 W x 144 D x 120 H in
Chamber Size35.5 W x 136 D x 83 H in
Approximate Capacity4 people
Blower Count3
Air-System ArrangementThree sectional blower systems
Area Classification BasisClass I, Division 2
Lighting BasisGroup C and D hazardous-location arrangement
Control MethodPneumatic access interface
Cabinet MaterialStainless steel
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

Applications

For coordinated personnel entry to higher-throughput clean hazardous processing facilities. The 12 ft body requires deliberate egress planning, distributed service access and verification that every selected component matches the site's gas or vapor classification.

Solutions for Your Application

Peak crews cannot be processed efficiently through the shorter classified air showers.Use the longer chamber and three air sections to stage approximately four occupants per cycle.
A long tunnel could obstruct emergency circulation in the classified area.Integrate the 144 in envelope, pneumatic release strategy and alternate egress route into the facility layout.

사용 가능한 옵션

Specify hazardous-location electrical package, pneumatic utilities, door arrangement, stainless grade, alarm interfaces and cycle programming. Final suitability depends on the documented area classification and process substances.

Planning a Explosion-Resistant Air Shower Tunnel 52 × 144 in specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.