クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / Cleanroom Air Filters / High-Capacity HEPA Filter 2294 CFM Extra-High-Flow
STJH-HIGH-CAPACITY-HEPA-H13-2294CFM

High-Capacity HEPA Filter 2294 CFM Extra-High-Flow

The maximum-flow H13 V-bank selection for 2294 cfm through one nominal 24-inch AHU opening.
  • 2294 cfm maximum airflow
  • Maximum internal media area
  • H13 critical-process duty
見積もりリクエスト 製品案内

商品紹介

This extra-high-capacity version uses the largest media-area selection in the 24 x 24 x 11.5 in H13 family. It delivers up to 2294 cfm at approximately 1.0 in. w.g. initial resistance, supporting high air-change systems where adding filter openings is impractical. Because the element has the greatest internal media volume, transport weight, withdrawal clearance and fan reserve deserve explicit review.

主要な特徴

Highest single-cell output

The maximum-media pack supplies the largest documented airflow from the common 24-inch enclosure.

Air-starved AHU response

Additional media area can relieve a face-area constraint without rebuilding the entire filter bank.

Longer loading path

The extensive V-bank surface spreads particulate loading across more microglass media.

技術的なパラメータ

Element Envelope24 x 24 x 11.5 in
Efficiency LevelH13 / 99.99% at 0.3 micron
Maximum Rated Airflow2294 cfm
Initial Pressure DifferentialAbout 1.0 in. w.g.
MediaWater-resistant microglass mini-pleat
V-Bank SelectionMaximum internal media area
CasingAnodized aluminum
AHU RequirementFull-depth 24-inch cell with adequate fan reserve
Changeout ConsiderationPlan support for the larger media mass
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

Applications

Applied in high-air-change pharmaceutical suites, medical facilities and critical process AHUs that need as much as 2294 cfm from each 24-inch cell. It should be chosen from an airflow and pressure calculation, not simply as a universal replacement for lower-capacity elements.

Solutions for Your Application

The critical area misses its airflow target although every filter opening is occupied.The maximum-media V-bank can raise a compatible cell to 2294 cfm when the fan has sufficient pressure reserve.
Operators struggle to withdraw a high-media-area filter without damaging the frame.Provide a straight service aisle and support the full enclosure during removal rather than pulling on one edge.

利用可能なオプション

Confirm efficiency selection, gasket position, actual dimensions, bank airflow balance and handling provisions for maximum-capacity service.

Planning a High-Capacity HEPA Filter 2294 CFM Extra-High-Flow specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ