The maximum-flow H13 V-bank selection for 2294 cfm through one nominal 24-inch AHU opening.
  • 2294 cfm maximum airflow
  • Maximum internal media area
  • H13 critical-process duty
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This extra-high-capacity version uses the largest media-area selection in the 24 x 24 x 11.5 in H13 family. It delivers up to 2294 cfm at approximately 1.0 in. w.g. initial resistance, supporting high air-change systems where adding filter openings is impractical. Because the element has the greatest internal media volume, transport weight, withdrawal clearance and fan reserve deserve explicit review.

Ana Özellikler

Highest single-cell output

The maximum-media pack supplies the largest documented airflow from the common 24-inch enclosure.

Air-starved AHU response

Additional media area can relieve a face-area constraint without rebuilding the entire filter bank.

Longer loading path

The extensive V-bank surface spreads particulate loading across more microglass media.

Teknik parametreler

Element Envelope24 x 24 x 11.5 in
Efficiency LevelH13 / 99.99% at 0.3 micron
Maximum Rated Airflow2294 cfm
Initial Pressure DifferentialAbout 1.0 in. w.g.
MediaWater-resistant microglass mini-pleat
V-Bank SelectionMaximum internal media area
CasingAnodized aluminum
AHU RequirementFull-depth 24-inch cell with adequate fan reserve
Changeout ConsiderationPlan support for the larger media mass
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Applications

Applied in high-air-change pharmaceutical suites, medical facilities and critical process AHUs that need as much as 2294 cfm from each 24-inch cell. It should be chosen from an airflow and pressure calculation, not simply as a universal replacement for lower-capacity elements.

Solutions for Your Application

The critical area misses its airflow target although every filter opening is occupied.The maximum-media V-bank can raise a compatible cell to 2294 cfm when the fan has sufficient pressure reserve.
Operators struggle to withdraw a high-media-area filter without damaging the frame.Provide a straight service aisle and support the full enclosure during removal rather than pulling on one edge.

Mevcut Seçenekler

Confirm efficiency selection, gasket position, actual dimensions, bank airflow balance and handling provisions for maximum-capacity service.

Planning a High-Capacity HEPA Filter 2294 CFM Extra-High-Flow specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim