ホーム / 製品 / Containment & Biosafety Equipment / Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding
STJH-CLOSED-RABS-4FT-ISO4-CHEMO

Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding

A compact four-foot negative-pressure closed RABS for small hazardous sterile batches, with a filtered transfer chamber and bag-out exhaust stage.
  • 4 ft standard length
  • ISO 4 negative-pressure chamber
  • 660 lb starting weight
見積もりリクエスト 製品案内

商品紹介

This is the shortest standard in the three-length family and is intended for small or medium compounding volumes. The 4 x 2.5 ft footprint concentrates the working sequence into one contained station, while the separate 12 in transfer chamber preserves a controlled route for supplies and finished doses.

主要な特徴

Compact oncology footprint

The four-foot length supports focused reconstitution work where pharmacy floor area is restricted.

Contained filter service

A bag-out arrangement allows the contaminated HEPA stage to be handled without open removal from its housing.

Interlocked transfer

The separate antechamber uses controlled doors and ISO 5 airflow for material movement.

技術的なパラメータ

Standard Length4 ft
Depth2.5 ft
Height6.75 ft
Starting Weight660 lb before size-dependent options
Main ChamberNegative pressure, ISO Class 4, vertical unidirectional airflow
Transfer Chamber12 in long, ISO Class 5 at static and dynamic conditions
AirflowAt least 400 cfm; at least 40 fpm at 6 in from filter face
FiltrationHEPA, nominal 99.99% DOP at 0.3 µm, with bag-out
Construction304L stainless chamber, 316L work surface and 3/8 in clear polycarbonate
カスタマイズGlove count, transfer-chamber side, lifting base, waste ports and pharmacy services can be configured for the intended hazardous-drug workload.

Applications

Low-volume chemotherapy reconstitution, clinical-trial hazardous doses and small hospital sterile compounding in a suitable negative-pressure room arrangement.

Solutions for Your Application

A hazardous-drug barrier must fit a small compounding room.Select the four-foot standard and confirm clearance around its 2.5 ft depth and lifting or fixed base.
Contaminated exhaust filters need a controlled replacement path.Use the integral bag-out housing and plan safe access to the filter service side.

利用可能なオプション

Two or four glove ports, one or two transfer chambers, caster or lifting stand, IV bar, outlets, shelves and waste or sharps connections may be selected.

Planning a Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。