Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Containment & Biosafety Equipment / Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding
STJH-CLOSED-RABS-4FT-ISO4-CHEMO

Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding

A compact four-foot negative-pressure closed RABS for small hazardous sterile batches, with a filtered transfer chamber and bag-out exhaust stage.
  • 4 ft standard length
  • ISO 4 negative-pressure chamber
  • 660 lb starting weight
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This is the shortest standard in the three-length family and is intended for small or medium compounding volumes. The 4 x 2.5 ft footprint concentrates the working sequence into one contained station, while the separate 12 in transfer chamber preserves a controlled route for supplies and finished doses.

Các tính năng chính

Compact oncology footprint

The four-foot length supports focused reconstitution work where pharmacy floor area is restricted.

Contained filter service

A bag-out arrangement allows the contaminated HEPA stage to be handled without open removal from its housing.

Interlocked transfer

The separate antechamber uses controlled doors and ISO 5 airflow for material movement.

Thông số kỹ thuật

Standard Length4 ft
Depth2.5 ft
Height6.75 ft
Starting Weight660 lb before size-dependent options
Main ChamberNegative pressure, ISO Class 4, vertical unidirectional airflow
Transfer Chamber12 in long, ISO Class 5 at static and dynamic conditions
AirflowAt least 400 cfm; at least 40 fpm at 6 in from filter face
FiltrationHEPA, nominal 99.99% DOP at 0.3 µm, with bag-out
Construction304L stainless chamber, 316L work surface and 3/8 in clear polycarbonate
Tùy chỉnhGlove count, transfer-chamber side, lifting base, waste ports and pharmacy services can be configured for the intended hazardous-drug workload.

Applications

Low-volume chemotherapy reconstitution, clinical-trial hazardous doses and small hospital sterile compounding in a suitable negative-pressure room arrangement.

Solutions for Your Application

A hazardous-drug barrier must fit a small compounding room.Select the four-foot standard and confirm clearance around its 2.5 ft depth and lifting or fixed base.
Contaminated exhaust filters need a controlled replacement path.Use the integral bag-out housing and plan safe access to the filter service side.

Các tùy chọn có sẵn

Two or four glove ports, one or two transfer chambers, caster or lifting stand, IV bar, outlets, shelves and waste or sharps connections may be selected.

Planning a Closed Restricted Access Barrier System 4 ft ISO 4 Negative-Pressure Hazardous-Compounding specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ