クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / Cleanroom HVAC Systems / Cleanroom Direct-Expansion Air Conditioning Unit 91 kW
STJH-CLEANROOM-DX-AIR-CONDITIONING-91KW

Cleanroom Direct-Expansion Air Conditioning Unit 91 kW

The largest selected precision DX build, providing 90.8 kW gross cooling and 7.5 m3/s airflow at a 1476 kg operating weight.
  • 90.8 kW gross cooling
  • 7.5 m3/s nominal airflow
  • 1476 kg operating weight
見積もりリクエスト 製品案内

商品紹介

This high-output configuration uses larger condenser plates, coil flow and compressor capacity to reach 90.8 kW gross cooling. Its 7.5 m3/s air volume, twin 2.72 l/s glycol paths and 1476 kg operating weight distinguish the hardware for high sensible-load clean production spaces.

主要な特徴

Largest selected DX duty

The refrigeration build supplies the highest capacity of the three cleanroom DX candidates.

Expanded glycol rejection

Twin 2.72 l/s paths carry the greater condenser heat load to the remote rejection system.

High-volume precision airflow

The 7.5 m3/s fan section supports a larger controlled area or denser process heat distribution.

技術的なパラメータ

Gross Cooling Capacity90.8 kW
Nominal Airflow7.5 m3/s
Glycol Flow2 x 2.72 l/s
Operating Weight1476 kg
Compressor TypeScroll
Refrigeration CircuitsDual circuit
Fan ArrangementHigh-output EC fan array
Heat RejectionRemote glycol-cooled condenser plates
Humidity FunctionsDehumidification with humidification and reheat options
カスタマイズDischarge geometry, heat rejection and environmental controls can be configured for the intended application and operating environment.

Applications

High sensible-load cleanrooms, electronics production floors, dense test areas and precision manufacturing suites using packaged DX cooling.

Solutions for Your Application

Peak equipment heat exceeds the capacity of the medium DX selection.Use the 90.8 kW build after separating sensible, latent and safety-margin portions of the load.
The heavier unit and greater glycol flow affect structure and pipe sizing.Coordinate the 1476 kg operating mass and both 2.72 l/s branches with the final base and heat-rejection loop.

利用可能なオプション

Airflow direction, reheat, humidifier, high-grade filters, pump package, compressor staging, leak alarms and supervisory controls are available.

Planning a Cleanroom Direct-Expansion Air Conditioning Unit 91 kW specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat