Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Cleanroom HVAC Systems / Cleanroom Direct-Expansion Air Conditioning Unit 91 kW
STJH-CLEANROOM-DX-AIR-CONDITIONING-91KW

Cleanroom Direct-Expansion Air Conditioning Unit 91 kW

The largest selected precision DX build, providing 90.8 kW gross cooling and 7.5 m3/s airflow at a 1476 kg operating weight.
  • 90.8 kW gross cooling
  • 7.5 m3/s nominal airflow
  • 1476 kg operating weight
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This high-output configuration uses larger condenser plates, coil flow and compressor capacity to reach 90.8 kW gross cooling. Its 7.5 m3/s air volume, twin 2.72 l/s glycol paths and 1476 kg operating weight distinguish the hardware for high sensible-load clean production spaces.

Ciri-ciri Utama

Largest selected DX duty

The refrigeration build supplies the highest capacity of the three cleanroom DX candidates.

Expanded glycol rejection

Twin 2.72 l/s paths carry the greater condenser heat load to the remote rejection system.

High-volume precision airflow

The 7.5 m3/s fan section supports a larger controlled area or denser process heat distribution.

Parameter teknikal

Gross Cooling Capacity90.8 kW
Nominal Airflow7.5 m3/s
Glycol Flow2 x 2.72 l/s
Operating Weight1476 kg
Compressor TypeScroll
Refrigeration CircuitsDual circuit
Fan ArrangementHigh-output EC fan array
Heat RejectionRemote glycol-cooled condenser plates
Humidity FunctionsDehumidification with humidification and reheat options
PenyesuaianDischarge geometry, heat rejection and environmental controls can be configured for the intended application and operating environment.

Applications

High sensible-load cleanrooms, electronics production floors, dense test areas and precision manufacturing suites using packaged DX cooling.

Solutions for Your Application

Peak equipment heat exceeds the capacity of the medium DX selection.Use the 90.8 kW build after separating sensible, latent and safety-margin portions of the load.
The heavier unit and greater glycol flow affect structure and pipe sizing.Coordinate the 1476 kg operating mass and both 2.72 l/s branches with the final base and heat-rejection loop.

Pilihan yang boleh didapati

Airflow direction, reheat, humidifier, high-grade filters, pump package, compressor staging, leak alarms and supervisory controls are available.

Planning a Cleanroom Direct-Expansion Air Conditioning Unit 91 kW specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami