Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Rumah > Produk-produk > / Produk-produk / Peralatan Cleanroom / Walk-Through Cleanroom Air Shower Tunnel
Peralatan Dekontaminasi Personil dan Bahan

Walk-Through Cleanroom Air Shower Tunnel (Towongan Mandi Udara)

An extended personnel-entry passage with selectable tunnel sections and an operating sequence matched to how people enter, shower and leave.
  • Extended Entry Passage
  • Sectional Length Options
  • Distributed Nozzle Panels
  • Selectable Cycle Logic
Permintaan untuk kutipan Browse Produk

Perkenalan produk

This air shower tunnel extends the personnel route through a series of nozzle-bearing enclosure sections. Return openings and accessible fan-filter compartments support recirculation along the selected cleaning length. Sectional construction can accommodate building access and different entrance footprints, with coated or stainless surfaces selected for the cleaning environment. A timed sequence coordinates the entry, active shower and exit stages for the intended group movement.

Fitur utama:

Distributed jet positions

Outlet panels extend beyond a compact chamber, allowing the selected active zones to follow the intended personnel route.

Sectional installation choice

Transportable sections can suit access restrictions where bringing a complete long enclosure into the building is impractical.

Length-specific service access

Filter and fan access can be allocated along the tunnel instead of treating only the entrance end as a maintenance face.

Clear operating guidance

Selected status indication distinguishes the entry, shower and exit stages for the agreed traffic sequence.

Solusi untuk aplikasi Anda

A personnel tunnel needs a repeatable group cycle as well as a workable installation footprint.

Shift-change arrivals exceed the planned entry schedule.Estimate capacity from the full entry, shower, purge and exit sequence, then choose group positions and an external waiting area around that cycle.
The active timer starts while the last user is still entering.Select door-closed and entry-detection logic that starts the intended group cycle only after loading is complete.
Outlet delivery varies along an extended passage.Match the fan, plenum, filter and nozzle zones for the complete active length rather than assuming that each enclosure section is an identical air-handling module.
Filter panels open into the waiting queue.Place service faces and component-withdrawal space outside the personnel staging and door-movement areas.

Aplikasi yang Tipis

Semiconductor shift entryLarge electronics plantsPharmaceutical campus gowningHigh-volume food hygiene entrances

Parameter teknis

The following are common selectable references for extended personnel air showers. Tunnel geometry and control mode are selected together; these entries are not a fixed occupancy or continuous-throughput rating.

Personnel RouteExtended straight-through passage with entrance and clean-side exit
Length ConfigurationSectional tunnel construction with selectable overall length and active jet zones
Nozzle ArrangementDirectional outlets distributed along opposing tunnel walls; ceiling outlets optional
Common Jet-Speed Option25 m/s-class nozzle-outlet configuration
Timed-Cycle Controller Option0–99 s adjustable shower timer for batch operation
Mode OperasiControlled group-entry cycle with timed shower and exit release
Air Cleaning CircuitRecirculating blower system with return-air prefilters and HEPA final filtration
Enclosure ChoicesCoated steel, Type 304 stainless steel or a combined coated/stainless body
Common Supply Variant380 V AC, 50 Hz
Door and Status ControlCoordinated entrance and exit sequence with cycle indication; interlocked doors in the batch configuration
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Alternative tunnel section lengthsCoated, stainless or mixed enclosure finishAdditional ceiling nozzle positionsHinged or automatic door packagesEntry and cycle-status indicatorsApplication-specific sensing and control sequence

A usual door-controlled tunnel uses a timed shower sequence. Added outlets and alternative door mechanisms are separate selections. Module count, occupancy and arrival rate are not interchangeable capacity ratings, and tunnel format alone does not imply nonstop moving-personnel operation.

Selection and Installation

Choose a defined group-entry sequence

A tunnel describes an extended personnel route, not a promise of uninterrupted walking. In the timed-batch arrangement, the group enters, the doors are controlled during the shower, and the exit is released at the end of the selected sequence. Keep the doors in their intended operating state; holding them open does not convert this arrangement into a continuously moving system.

Estimate traffic from the complete cycle

Record peak arrivals, permitted standing positions, entry and exit time, selected shower duration and any purge or wait delay. Allow room for the waiting group outside the door travel and service zones. More nozzle bays or a longer shell do not by themselves establish an occupancy limit, people per minute or zero waiting.

Keep the long installation serviceable

Check the outer footprint, clear passage and door openings separately, including section joints and fully open door projections. Plan how the largest enclosure section reaches the installation room, then reserve the filter-withdrawal and fan-maintenance faces along its length. The queue and adjacent equipment must not occupy those service clearances.

Select one matched tunnel package

Choose the fan arrangement, nozzle zones, filter area and return locations together for the active length. A modular shell does not prove that every bay has an independent blower or identical outlet velocity. Compare electrical input and sound at the same airflow and filter condition, and specify normal entry, cycle completion, emergency release and power-loss behavior. For a holding-chamber arrangement rather than an extended route, compare the multi-person cleanroom air shower.

Planning a Walk-Through Cleanroom Air Shower Tunnel specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Rumah > Produk-produk >

Produk-produk

Berita Berita

Tentang kami

Hubungi Kami Hubungi Kami Hubungi Kami