Kabinet Keamanan Biologi Kelas III
- Gas-Tight Stainless Chamber
- Fixed Glove and Sleeve Ports
- Negative-Pressure Operation
- Controlled Double-Door Transfer
Perkenalan produk
The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.
Fitur utama:
Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.
A double-door transfer chamber controls material entry and removal.
Negative pressure directs any inward leakage toward the filtered exhaust.
Pressure-hold and glove-integrity connections support routine barrier checks.
Solusi untuk aplikasi Anda
A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.
Aplikasi yang Tipis
Parameter teknis
Typical configurable construction ranges for a Class III biological safety cabinet are listed below.
| Bahan inti | Fully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies |
|---|---|
| Ketebalan Panel (Panel Thickness) | 40-80mm bagian layanan dan kamar kulit ganda |
| Efektif lebar | 1200-3000 mm usable glovebox width |
| Panjang maksimum | Up to 4000 mm overall chamber length |
| Baja menghadap ketebalan | 2.0-3.0 mm welded SUS316L chamber shell |
| Kepadatan inti (core density) | Sekitar 8000 kg/mmaine untuk bahan ruang SUS316L |
| Konduktivitas Termal (Thermal Conductivity) | 14 - 16 W / (m · K) untuk baja tahan karat austenitic |
| Permukaan selesai | Electropolished SUS316L interior with radiused welded corners |
| Jenis Bersama | Continuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Class III Biological Safety Cabinet specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Portugis
Bahasa Spanyol
Bahasa Melayu
Bahasa IndonesiaSaat ini
Bahasa Jerman
Bahasa Turki
Bahasa Vietnam
Bahasa Perancis: Bahasa Perancis
Bahasa Rusia
Bahasa Arab
Bahasa Thailand
Bahasa Jepang
Bahasa Korea