Kelas III Kabinet Keselamatan Biologi
- Gas-Tight Stainless Chamber
- Fixed Glove and Sleeve Ports
- Negative-Pressure Operation
- Controlled Double-Door Transfer
Pengenalan Produk
The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.
Ciri-ciri Utama
Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.
A double-door transfer chamber controls material entry and removal.
Negative pressure directs any inward leakage toward the filtered exhaust.
Pressure-hold and glove-integrity connections support routine barrier checks.
Penyelesaian untuk permohonan anda
A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.
Permohonan yang biasa
Parameter teknikal
Typical configurable construction ranges for a Class III biological safety cabinet are listed below.
| Bahan Teras | Fully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies |
|---|---|
| Ketebalan Panel | 40-80 mm double-skin chamber and service sections |
| Lebar berkesan | 1200-3000 mm usable glovebox width |
| Panjang maksimum | Up to 4000 mm overall chamber length |
| Keluli Menghadapi Ketebalan | 2.0-3.0 mm welded SUS316L chamber shell |
| Ketumpatan teras | Approximately 8000 kg/m³ for SUS316L chamber material |
| Kekonduksian Terma | 14-16 W / (m · K) untuk keluli tahan karat austenit |
| Kemasan permukaan | Electropolished SUS316L interior with radiused welded corners |
| Jenis Bersatu | Continuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Class III Biological Safety Cabinet specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jerman
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)
Bahasa Perancis
Bahasa Rusia
Bahasa Arab (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)