Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Cleanroom Air Shower Tunnel Three-Section Walk-Through
STJH-WALK-THROUGH-AIR-SHOWER-TUNNEL-3SECTION

Cleanroom Air Shower Tunnel Three-Section Walk-Through

A medium-length three-module air shower tunnel with 102 adjustable jets and three filtered blower sections.
  • 4115 mm tunnel depth
  • Three blower and HEPA modules
  • 102 total adjustable nozzles
Demander un devis. Browse les produits

Introduction de produit

The three-section tunnel extends the standard-profile path to 4115 mm. Three 5 hp blower and HEPA modules serve 96 wall nozzles and six ceiling jets, adding one complete cleaning section beyond the compact model. This geometry supports a longer exposure path and moderate pedestrian throughput without reaching the four-section footprint.

Key Features

Extended exposure distance

A third 54 in section lengthens the active path for personnel moving at a controlled pace.

Sectional serviceability

Each module has its own blower, HEPA stage and access panels for a clearly divided air system.

Expanded jet field

Ninety-six wall and six ceiling nozzles distribute air along the full 4.1 m enclosure.

Paramètres techniques

External Dimensions1264 W x 4115 D x 2946 H mm
Tunnel Sections3
Nominal Section Depth54 in
Motors3 x 5 hp, three phase
HEPA Stages3
Wall Jets96
Overhead Jets6
Air Delivery per SectionApproximately 1900 CFM
User InterfaceTouchscreen microprocessor control
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

Designed for medium-throughput pedestrian entrances, batch gown cleaning and research or manufacturing facilities needing a longer transition. The added centre module allows more exposure at the same walking speed.

Solutions for Your Application

Two sections provide too little travel time for the entry protocol.Add the third active module to extend the high-velocity cleaning path by 54 in.
A long integrated air system would be difficult to service.Use the sectional arrangement with separate blower, filter and access components for each module.

Options disponibles

Select shell material, lighting, interlocks, HMI timing, door configuration and optional 90-degree section placement. Wider modules can be engineered where the traffic path requires them.

Planning a Cleanroom Air Shower Tunnel Three-Section Walk-Through specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact