Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Équipement Cleanroom / Weighing Booth 6 ft Recirculating Double-HEPA
STJH-NEGATIVE-PRESSURE-WEIGHING-6FT-DOUBLE-HEPA

Weighing Booth 6 ft Recirculating Double-HEPA

A large recirculating containment booth with serial HEPA filtration and bag-in/bag-out service for higher-hazard weighing workflows.
  • Six-foot process width
  • Two HEPA stages in series
  • Bag-in / Bag-out changement de filtre
Demander un devis. Browse les produits

Introduction de produit

This six-foot booth expands the work zone for multiple balances, bulk containers or two operators while using two HEPA filters in series. Bag-in/bag-out service limits direct contact with loaded filters during maintenance. The unit recirculates filtered air, so material potency, occupational limits and decontamination strategy must be evaluated before selection.

Key Features

Redundant filtration path

Serial HEPA stages add a second particle barrier before air returns to the room.

Contained maintenance

BIBO housings support removal of loaded filters inside protective bags.

Expanded workflow area

The six-foot opening accommodates larger containers, separated tasks or dual-operator layouts.

Paramètres techniques

Nominal Width6 ft
Airflow ModeNegative-pressure recirculating
Filter ArrangementTwo HEPA filters in series
Filter ServiceBag-in/bag-out
BlowerBuilt-in recirculation fan
ExhaustReturned to room after filtration
Work CapacityLarge-container or multi-position setup
MonitoringAirflow and filter-status options
InteriorSmooth cleanable work zone
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

For larger hazardous-drug, active-pharmaceutical-ingredient or potent-powder weighing processes where a recirculating system is justified and contained filter maintenance is required.

Solutions for Your Application

A single filter stage provides insufficient redundancy for the assessed powder hazard.Pass exhaust through two HEPA filters in series before room return.
Changing a contaminated filter can expose maintenance personnel.Use bag-in/bag-out housings to contain the filter during removal and replacement.

Options disponibles

Configure work surface, glove or sash accessories, service utilities, scanning ports, alarms and decontamination provisions. Final recirculation approval follows the handled compound assessment.

Planning a Weighing Booth 6 ft Recirculating Double-HEPA specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact