Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Equipamento de Cleanroom / Weighing Booth 6 ft Recirculating Double-HEPA
STJH-NEGATIVE-PRESSURE-WEIGHING-6FT-DOUBLE-HEPA

Weighing Booth 6 ft Recirculating Double-HEPA

A large recirculating containment booth with serial HEPA filtration and bag-in/bag-out service for higher-hazard weighing workflows.
  • Six-foot process width
  • Two HEPA stages in series
  • Bag-in/bag-out filter change
Solicite um orçamento. Browse produtos

Introdução do produto

This six-foot booth expands the work zone for multiple balances, bulk containers or two operators while using two HEPA filters in series. Bag-in/bag-out service limits direct contact with loaded filters during maintenance. The unit recirculates filtered air, so material potency, occupational limits and decontamination strategy must be evaluated before selection.

Características-chave

Redundant filtration path

Serial HEPA stages add a second particle barrier before air returns to the room.

Contained maintenance

BIBO housings support removal of loaded filters inside protective bags.

Expanded workflow area

The six-foot opening accommodates larger containers, separated tasks or dual-operator layouts.

Parâmetros técnicos

Nominal Width6 ft
Airflow ModeNegative-pressure recirculating
Filter ArrangementTwo HEPA filters in series
Filter ServiceBag-in/bag-out
BlowerBuilt-in recirculation fan
ExhaustReturned to room after filtration
Work CapacityLarge-container or multi-position setup
MonitoringAirflow and filter-status options
InteriorSmooth cleanable work zone
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For larger hazardous-drug, active-pharmaceutical-ingredient or potent-powder weighing processes where a recirculating system is justified and contained filter maintenance is required.

Solutions for Your Application

A single filter stage provides insufficient redundancy for the assessed powder hazard.Pass exhaust through two HEPA filters in series before room return.
Changing a contaminated filter can expose maintenance personnel.Use bag-in/bag-out housings to contain the filter during removal and replacement.

Opções disponíveis

Configure work surface, glove or sash accessories, service utilities, scanning ports, alarms and decontamination provisions. Final recirculation approval follows the handled compound assessment.

Planning a Weighing Booth 6 ft Recirculating Double-HEPA specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato