Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Containment & Biosafety Equipment / Class II Type B2 Biological Safety Cabinet 1200 mm Temperature-Controlled
STJH-CLASS-II-TYPE-B2-BIOLOGICAL-SAFETY-CABINET-1200-TEMP

Class II Type B2 Biological Safety Cabinet 1200 mm Temperature-Controlled

A four-foot total-exhaust B2 cabinet with a dedicated temperature-controlled work area for sensitive samples or instruments.
  • Local temperature-controlled area
  • 0–50 °C operating range
  • Type B2 total exhaust
Demander un devis. Browse les produits

Introduction de produit

This variant integrates a local controlled surface area into the B2 work zone. An external circulator supplies the approximately 270 x 300 mm zone for temperature-sensitive handling while the cabinet retains its total-exhaust airflow architecture.

Key Features

Controlled process surface

The dedicated zone supports temperature-sensitive sample preparation inside the protected cabinet.

External circulator connection

A compatible circulator supplies controlled fluid through the work-surface system.

B2 airflow architecture

Cabinet air is exhausted to the facility rather than returned to the laboratory.

Paramètres techniques

Nominal Cabinet Width1219 mm
Cabinet ClassClass II Type B2
Controlled Work AreaApproximately 270 x 300 mm
Temperature Range0–50 °C with external circulator
Circulator Flow1.5–1.9 L/min
Exhaust Architecture100% total exhaust
Facility ConnectionHard duct
Service FeaturesCable portals and instrument service fixture
Primary UseTemperature-sensitive contained handling
CustomisationControlled-zone location, circulator connections and cabinet services can be configured for the process.

Applications

Temperature-sensitive biological sample handling, cooled preparation and instrument work requiring Type B2 total exhaust.

Solutions for Your Application

Samples warm during manipulation inside a standard cabinet.Place the critical step on the circulator-fed controlled work area.
Fluid connections could interfere with cabinet airflow or cleaning.Route supply and return lines through dedicated service penetrations outside the active grille paths.

Options disponibles

Controlled-zone position, circulator connection, service penetrations and base stand can be configured.

Planning a Class II Type B2 Biological Safety Cabinet 1200 mm Temperature-Controlled specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact