Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Cleanroom Air Filters / Bag-In/Bag-Out HEPA Filter Housing 1 × 1 Gel-Seal
STJH-BIBO-HEPA-HOUSING-GEL-1X1

Bag-In/Bag-Out HEPA Filter Housing 1 × 1 Gel-Seal

A stainless one-cell containment housing that seats a gel-seal HEPA filter from the protected service side.
  • Positive gel-seal interface
  • One full-size filter
  • 304 or 316 stainless options
Demander un devis. Browse les produits

Introduction de produit

This single-cell version substitutes positive gel-seal engagement for the gasket compression used by the companion housing. The welded cabinet is available in 304 or 316 stainless construction and supports bag-in/bag-out maintenance for critical exhaust service. Gel engagement can provide a repeatable knife-edge interface, but the selected filter trough, sealant and operating temperature must remain compatible throughout the service life.

Key Features

Knife-edge gel engagement

The housing edge enters the filter gel trough to form a continuous perimeter seal without relying on gasket compression.

Corrosion-resistant cabinet

Stainless material options suit aggressive washdown or process-exhaust environments better than painted carbon steel.

Bagged filter exchange

The side change system retains contaminants while the spent filter is transferred from the cabinet.

Paramètres techniques

Filter CapacityOne full-size HEPA filter
Filter SealGel trough with housing knife edge
Housing Material14- or 11-gauge 304 or 316 stainless steel options
Cabinet ConstructionFully welded containment housing
Change MethodBag-in/bag-out
AccessSide service door and bagging ring
Housing TestPressure-decay-tested construction family
Flow ArrangementSelected horizontal or vertical configuration
Service RequirementGel compatibility and knife-edge inspection
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Applications

For critical pharmaceutical, chemical and radioisotope exhaust systems where a stainless pressure boundary and gel-seal HEPA interface are preferred.

Solutions for Your Application

Gel is damaged, contaminated or incompatible with the process temperature.Specify the gel formulation for the operating range and inspect the trough and knife edge during every contained change.
The stainless grade is inadequate for the exhaust chemistry or cleaning agent.Select 304 or 316 construction after reviewing the actual condensate, disinfectant and airborne chemical exposure.

Options disponibles

Choose stainless grade, gauge, filter dimensions, gel type, bagging material, test ports, airflow direction and optional prefilter stage.

Planning a Bag-In/Bag-Out HEPA Filter Housing 1 × 1 Gel-Seal specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.