Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / Cleanroom HVAC Systems / Energy Recovery Ventilator 200 CFM
STJH-ENERGY-RECOVERY-VENTILATOR-200CFM

Energy Recovery Ventilator 200 CFM

The largest EV cabinet in the selected range for suites, factory offices and conference areas.
  • 100-200 CFM range
  • L-100-G5-class static core
  • 24 VAC transformer and relay controls

Produkteinführung

This model delivers 100-200 CFM and uses the larger L-100-G5-class static plate core and cabinet. A 24 VAC transformer and relay package supports integration with room ventilation controls rather than a simple line-cord-only arrangement. It serves larger clean-support suites and conference areas, while supply and exhaust must be balanced against actual duct resistance to protect surrounding pressure relationships.

Key Features

Largest selected EV airflow

The expanded cabinet serves suites and occupied areas beyond the two smaller local units.

Static plate recovery

The fixed core transfers total energy without rotating wheel maintenance.

Control-system interface

A transformer and relay package supports remote enable and coordinated ventilation operation.

Technische Parameter

Airflow Range100-200 CFM
InstallationIndoor, any orientation
Recovery CoreL-100-G5-class static plate
Controls24 VAC transformer and relay package
FansDirect-drive supply and exhaust
Air StreamsBalanced outdoor and return exhaust
RecoverySensible and latent
FiltrationReplaceable airstream filters
Primary DutyLarge support-suite ventilation
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Applications

For larger clean-support suites, factory offices, conference rooms and low-risk controlled spaces requiring up to 200 CFM ventilation.

Solutions for Your Application

A 200 CFM exhaust offset disturbs the adjacent cleanroom pressure cascade.Coordinate ERV supply and exhaust setpoints with the building air-balance schedule and room-pressure controls.
Frost restricts the static core during cold outdoor conditions.Apply the selected defrost or intermittent control strategy and verify condensate management for the installation orientation.

Verfügbare Optionen

Confirm airflow, external pressure, core suitability, voltage, 24 VAC controls, filters, frost strategy, balancing, mounting and service access.

Planning a Energy Recovery Ventilator 200 CFM specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt