Comfort air conditioning does not address the process moisture load.
Compare dedicated dehumidification or dry-room systems using the required humidity or dew point, outdoor-air load and process moisture sources.
Build an air-conditioning system around the conditions your production needs, not just the room size. Explore air handling units, cooling and heating equipment, humidifiers, dehumidifiers and fans for cleanroom applications. With the process loads, outdoor conditions and available services defined, we can help you compare equipment configurations that address temperature, moisture and airflow together while keeping maintenance needs in view.

Combine the air-treatment functions your facility needs in a suitable AHU arrangement. Compare outdoor-air duty, recirculation, cabinet orientation, coil sections and maintenance access.
Explore Products
Choose the cooling or heating source around required capacity, utility temperatures and site conditions. Compare air-cooled, water-cooled and heat-pump options with the connected equipment duty.
Explore Products
Support water-based HVAC circuits with pumps, cooling towers and heat exchangers. Match flow, pressure, heat-transfer duty and water conditions to the overall system arrangement.
Explore Products
Provide cooling, heating or reheat at the correct air-treatment stage. Compare water, steam, electric and direct-expansion options using available services and the required leaving-air condition.
Explore Products
Add moisture with a method suitable for the air system and process. Review water or steam quality, absorption distance, control range and maintenance needs before selection.
Explore Products
Manage moisture loads with refrigerant or desiccant equipment. Define the desired humidity or dew point, outdoor-air contribution and process conditions to compare suitable configurations.
Explore Products
Move supply, return or exhaust air at the required operating point. Consider airflow, system pressure, sound, materials and any process-specific exhaust hazards.
Explore Products
Explore air-to-air recovery arrangements where the system and contamination strategy permit them. Compare airstream separation needs, maintenance access and seasonal conditions rather than assuming every exhaust is reusable.
Explore ProductsCleanroom HVAC must respond to heat from equipment and people, moisture from outdoor air and processes, and the airflow required by the facility. An air handling unit brings several treatment stages together, while chillers, heat exchangers, pumps and heaters provide the supporting services that allow those stages to operate.
Moisture control deserves particular care. Cooling-based dehumidification and desiccant systems work differently, and dry-room requirements may extend beyond ordinary air-conditioning capability. Humidification selection likewise depends on the air conditions, water or steam quality, absorption space and the process being served.
The best equipment arrangement is also one your team can operate and maintain. Filter access, coil cleaning, condensate drainage, fan servicing and control interfaces should be considered early. Share the design conditions and plant-room constraints so the proposed supply package can be aligned with your facility's engineering design.
Compare dedicated dehumidification or dry-room systems using the required humidity or dew point, outdoor-air load and process moisture sources.
Review sectional AHUs and different cabinet orientations together with the service side and component removal clearances.
Use a coordinated schedule of air volumes, coil duties and utility temperatures to match the main unit and supporting equipment.
Define summer and winter design points and assess fresh-air treatment, reheat and suitable energy-recovery options within the system design.
Air treatment for rooms where process temperature, humidity and supply-air conditions must be considered together.
Dehumidification and conditioned-air equipment for moisture-sensitive materials and manufacturing operations.
Fresh-air, recirculation and exhaust equipment serving controlled production rooms and associated utility areas.
No products match your selection. Try another product type or a shorter search term.
Floor area is only a starting point. Process heat, moisture, outdoor-air quantity, room targets and airflow requirements are needed to define meaningful equipment duties.
Consider it when the process needs moisture control that is difficult to achieve with cooling alone, particularly lower-dew-point applications. Selection requires the target condition and incoming moisture load.
Yes. Include the required cooling, heating, pumping and humidity-control duties in your request. The final equipment combination should remain consistent with the facility designer's air and utility calculations.
Share your design conditions, airflow schedule and available utilities to compare air-treatment equipment and request a coordinated quotation.