موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
الرئيسية / المنتجات / Cleanroom HVAC Systems / Energy Recovery Ventilator 200 CFM
STJH-ENERGY-RECOVERY-VENTILATOR-200CFM

Energy Recovery Ventilator 200 CFM

The largest EV cabinet in the selected range for suites, factory offices and conference areas.
  • 100-200 CFM range
  • L-100-G5-class static core
  • 24 VAC transformer and relay controls
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This model delivers 100-200 CFM and uses the larger L-100-G5-class static plate core and cabinet. A 24 VAC transformer and relay package supports integration with room ventilation controls rather than a simple line-cord-only arrangement. It serves larger clean-support suites and conference areas, while supply and exhaust must be balanced against actual duct resistance to protect surrounding pressure relationships.

الخصائص الرئيسية

Largest selected EV airflow

The expanded cabinet serves suites and occupied areas beyond the two smaller local units.

Static plate recovery

The fixed core transfers total energy without rotating wheel maintenance.

Control-system interface

A transformer and relay package supports remote enable and coordinated ventilation operation.

المعلمات الفنية

Airflow Range100-200 CFM
InstallationIndoor, any orientation
Recovery CoreL-100-G5-class static plate
Controls24 VAC transformer and relay package
FansDirect-drive supply and exhaust
Air StreamsBalanced outdoor and return exhaust
RecoverySensible and latent
FiltrationReplaceable airstream filters
Primary DutyLarge support-suite ventilation
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

Applications

For larger clean-support suites, factory offices, conference rooms and low-risk controlled spaces requiring up to 200 CFM ventilation.

Solutions for Your Application

A 200 CFM exhaust offset disturbs the adjacent cleanroom pressure cascade.Coordinate ERV supply and exhaust setpoints with the building air-balance schedule and room-pressure controls.
Frost restricts the static core during cold outdoor conditions.Apply the selected defrost or intermittent control strategy and verify condensate management for the installation orientation.

الخيارات المتاحة

Confirm airflow, external pressure, core suitability, voltage, 24 VAC controls, filters, frost strategy, balancing, mounting and service access.

Planning a Energy Recovery Ventilator 200 CFM specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا