Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Thiết bị phòng sạch / Vertical Laminar Flow Clean Bench 2 ft
STJH-VERTICAL-CLEAN-BENCH-2FT

Vertical Laminar Flow Clean Bench 2 ft

The smallest vertical clean bench width for non-hazardous sample preparation in a limited laboratory footprint.
  • 2 ft compact work width
  • 45-65 fpm vertical downflow
  • ISO Class 5 work zone
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This 2 ft bench directs HEPA-filtered air downward over a compact work zone. A nominal 45-65 fpm downflow, 99.99% efficient HEPA filter at 0.3 µm and aerodynamic sash opening support ISO Class 5 conditions for non-hazardous work. Its narrow width is best for one compact instrument or a tightly defined manual step rather than broad assembly layouts.

Các tính năng chính

Small laboratory footprint

The two-foot width fits short benches and dedicated sample-preparation corners.

Product-focused downflow

HEPA-filtered air descends across the work surface to reduce particulate deposition on non-hazardous materials.

Adjustable fan output

A variable-speed blower supports velocity setup as filter resistance changes over service life.

Thông số kỹ thuật

Nominal Width2 ft
Airflow DirectionVertical downflow
Downflow Velocity45-65 fpm
Final FilterHEPA, 99.99% at 0.3 µm
Work-Zone ConditionISO Class 5
Sash Opening9.4 in nominal
Sash Material6.35 mm tempered safety glass
Blower ControlVariable speed
Utility AccessTwo side utility ports
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For PCR setup, media plating and small sterile non-hazardous preparation tasks. This clean bench protects the work, not the operator, and must not be used for biohazards, toxins or radionuclides.

Solutions for Your Application

A standard four-foot bench consumes too much scarce laboratory counter space.Use the two-foot model for one compact instrument and a narrowly defined clean task.
Operators may mistake a clean bench for personnel containment.Limit the unit to non-hazardous work and select a containment cabinet where operator protection is required.

Các tùy chọn có sẵn

Choose electrical configuration, airflow monitor, UV lamp package, stand and work-surface material. Utility port fittings can be matched to the process connection.

Planning a Vertical Laminar Flow Clean Bench 2 ft specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat