Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Vertical Air Handling Unit 1500 CFM
STJH-VERTICAL-AIR-HANDLING-UNIT-1500CFM

Vertical Air Handling Unit 1500 CFM

A compact upright 1500 CFM air handler using a 34 x 34.1 inch footprint for small controlled-area mechanical closets.
  • 1500 CFM nominal airflow
  • 34 x 34.1 inch footprint
  • Compact upright arrangement
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The smallest selected vertical cabinet places the fan above or below the coil within a 34 x 34.1 inch footprint. Its upright airflow arrangement minimizes floor area while providing a dedicated coil, filter and drain section for a small controlled zone.

Các tính năng chính

Minimal floor footprint

The square upright cabinet uses vertical space instead of extending across a crowded mechanical room.

Selectable coil medium

Water, DX or steam coil options allow the small cabinet to connect to the available building utility.

Contained condensate section

A drain-pan arrangement below the cooling coil manages moisture within the vertical casing.

Thông số kỹ thuật

Nominal Airflow1500 CFM
Cabinet Width34 in
Cabinet Length34.1 in
Cabinet Height46.33-51.40 in depending on fan selection
Airflow ArrangementVertical
Coil OptionsChilled water, hot water, DX or steam
Casing ConstructionSingle- or double-wall option
Filter SectionFlat or angled arrangement as selected
Drain PanCooling-coil condensate pan
Tùy chỉnhCoil, fan and access orientation can be configured for the intended application and operating environment.

Applications

Small controlled rooms, clean support areas, laboratories and mechanical closets where an upright air handler preserves floor access.

Solutions for Your Application

A horizontal cabinet would block the narrow mechanical-room aisle.Use the 34 inch-wide vertical footprint and place service access toward the open aisle.
The project utility may change between chilled water and direct expansion.Select the coil and matching drain or piping connections for the final thermal source.

Các tùy chọn có sẵn

Coil medium, casing wall construction, filter layout, fan type, access side, drain-pan material and control sensors can be selected.

Planning a Vertical Air Handling Unit 1500 CFM specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.