Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Containment & Biosafety Equipment / High-Potency Containment Isolator 1200 mm Two-Glove
STJH-HIGH-POTENCY-CONTAINMENT-ISOLATOR-1200-2G

High-Potency Containment Isolator 1200 mm Two-Glove

A compact two-glove negative-pressure isolator for high-potency weighing and dispensing with one pass chamber.
  • 1200 mm process chamber
  • Two oval glove ports
  • 20 m³/h normal exhaust
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This smallest retained high-potency model uses a 1200 mm process chamber and two oval glove ports. Its normal-run exhaust is 20 m³/h, the lowest in the family, while the stainless chamber and double-stage H14 exhaust path support contained weighing within a compact external envelope.

Các tính năng chính

Compact HPAPI station

The two-glove chamber concentrates weighing and dispensing around one operator position.

Double exhaust filtration

Two push-push H14 filter stages provide a contained service approach on the exhaust path.

Breach-response airflow

The system has a higher published exhaust duty for operation following a defined barrier breach condition.

Thông số kỹ thuật

External Dimensions with One Pass Chamber1990 x 924 x 2275 mm
Internal Process Chamber1200 x 633 x 842 mm
Glove Ports2 oval ports, 200 x 300 mm
Chamber PressureNegative
Airflow PatternTurbulent flow, more than 30 air changes per hour
Normal-Run Exhaust20 m³/h at 300 Pa
Breach Exhaust100 m³/h at 900 Pa
Exhaust FiltrationDouble-stage H14 push-push, nominal 99.995% at 0.3 µm MPPS
Internal Chamber4.0 mm 316L stainless steel, Ra ≤ 0.40 µm
Tùy chỉnhPass chamber, weighing equipment and transfer interfaces can be configured for the potency and batch workflow.

Applications

Compact high-potency active ingredient weighing, dispensing and small-batch sampling behind a two-glove negative-pressure barrier.

Solutions for Your Application

A larger isolator adds unnecessary exhaust demand to a focused weighing operation.Use the 1200 mm chamber where equipment and batch staging fit within the two-glove reach pattern.
Exhaust-filter replacement could expose the service operator.Use the double-stage push-push arrangement with the site's established contained filter-change procedure.

Các tùy chọn có sẵn

Pass-chamber arrangement, integrated scales, transfer valves and contained waste interfaces can be selected for the process.

Planning a High-Potency Containment Isolator 1200 mm Two-Glove specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức