STJH-HIGH-POTENCY-CONTAINMENT-ISOLATOR-1200-2G

High-Potency Containment Isolator 1200 mm Two-Glove

A compact two-glove negative-pressure isolator for high-potency weighing and dispensing with one pass chamber.
  • 1200 mm process chamber
  • Two oval glove ports
  • 20 m³/h normal exhaust
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This smallest retained high-potency model uses a 1200 mm process chamber and two oval glove ports. Its normal-run exhaust is 20 m³/h, the lowest in the family, while the stainless chamber and double-stage H14 exhaust path support contained weighing within a compact external envelope.

Ciri-ciri Utama

Compact HPAPI station

The two-glove chamber concentrates weighing and dispensing around one operator position.

Double exhaust filtration

Two push-push H14 filter stages provide a contained service approach on the exhaust path.

Breach-response airflow

The system has a higher published exhaust duty for operation following a defined barrier breach condition.

Parameter teknikal

External Dimensions with One Pass Chamber1990 x 924 x 2275 mm
Internal Process Chamber1200 x 633 x 842 mm
Glove Ports2 oval ports, 200 x 300 mm
Chamber PressureNegative
Airflow PatternTurbulent flow, more than 30 air changes per hour
Normal-Run Exhaust20 m³/h at 300 Pa
Breach Exhaust100 m³/h at 900 Pa
Exhaust FiltrationDouble-stage H14 push-push, nominal 99.995% at 0.3 µm MPPS
Internal Chamber4.0 mm 316L stainless steel, Ra ≤ 0.40 µm
PenyesuaianPass chamber, weighing equipment and transfer interfaces can be configured for the potency and batch workflow.

Applications

Compact high-potency active ingredient weighing, dispensing and small-batch sampling behind a two-glove negative-pressure barrier.

Solutions for Your Application

A larger isolator adds unnecessary exhaust demand to a focused weighing operation.Use the 1200 mm chamber where equipment and batch staging fit within the two-glove reach pattern.
Exhaust-filter replacement could expose the service operator.Use the double-stage push-push arrangement with the site's established contained filter-change procedure.

Pilihan yang boleh didapati

Pass-chamber arrangement, integrated scales, transfer valves and contained waste interfaces can be selected for the process.