Extended process coverage
The 1500 mm axis follows long tools and several adjacent work positions.
This long EFU uses a 1000 x 1500 mm footprint to follow extended automated equipment and multi-station cells. The 160 + 35 mm cabinet carries a 50 mm H14 filter, provides 260 Pa static pressure and uses the highest listed power range in the group at 110-190 W. Its rectangular coverage is selected for process length rather than maximum static pressure.
The 1500 mm axis follows long tools and several adjacent work positions.
A 50 mm H14 filter provides the specified final filtration across the long face.
The 260 Pa static point prioritizes broad equipment coverage while retaining resistance capability.
| Nominal Format | 3 x 5 |
|---|---|
| Footprint | 1000 x 1500 mm |
| Cabinet Height | 160 + 35 mm |
| Static Pressure | 260 Pa |
| Power Input | 110-190 W |
| Sound Level | 46-53 dBA |
| Final Filter | H14, 50 mm |
| Installation | Long equipment-roof or process-cell mounting |
| Service Clearance | Required along the 1500 mm axis |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Recommended for long automated production equipment, multi-station cells and extended mini-environments. Mounting support, access and airflow distribution should be checked across the entire 1500 mm length.
Confirm the H14 seal, power supply, fan control, equipment interface and lifting method. Final output should be verified across the complete tool opening.
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.