Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Cleanroom HVAC Systems / Direct Steam Injection Humidifier 1/2-Inch Inlet
STJH-DIRECT-STEAM-INJECTION-HUMIDIFIER-12INLET

Direct Steam Injection Humidifier 1/2-Inch Inlet

The smallest stainless steam-injection body for clean ducts supplied with dry conditioned plant steam.
  • 1/2 in NPT steam inlet
  • Compact 1100-class body
  • 0.30-3.66 m manifold range
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This compact direct-injection humidifier uses a 1/2 in NPT steam inlet and the smallest body cross-section in the selected series. Stainless wetted parts and manifold lengths from 0.30 to 3.66 m allow the assembly to fit small clean AHU ducts. Because steam comes from the plant system rather than an integral boiler, separator, trap, condensate drainage and control-valve sizing determine whether the discharge remains dry.

Các tính năng chính

Small duct package

The compact body and inlet suit low steam flow and restricted AHU wall space.

Stainless wetted path

300-series stainless components resist condensate exposure in clean-air service.

Plant-steam efficiency

The unit conditions and meters available steam without a local electrical boiling vessel.

Thông số kỹ thuật

Steam Inlet1/2 in NPT
Body ClassCompact 1100 cross-section
Wetted Material300-series stainless steel
Manifold Length0.30-3.66 m range
Steam SourceConditioned plant steam
ControlModulating steam valve
Condensate ManagementSeparator, trap and drain connection
InstallationSmall clean AHU duct
DistributionSingle dispersion manifold by selection
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For small cleanroom air handlers and supply ducts where dry conditioned plant steam is available near the unit.

Solutions for Your Application

Wet plant steam spits condensate from the small dispersion manifold.Provide correct separator, trap, supply pitch and drainage before the control valve and manifold.
The 1/2 in valve cannot deliver the peak humidity load at available steam pressure.Size the inlet and valve from actual mass flow and pressure drop, then choose a larger body where required.

Các tùy chọn có sẵn

Specify plant steam pressure, required output, valve characteristic, manifold length, separator, trap, drain, actuator and duct location.

Planning a Direct Steam Injection Humidifier 1/2-Inch Inlet specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.