A compact negative-pressure Class I cabinet for single-operator procedures that need personnel and environmental protection without product protection.
  • 610 mm work width
  • Negative-pressure containment
  • HEPA-filtered exhaust
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The 610 mm nominal work width gives one operator a contained bench space while occupying less laboratory frontage than the wider models. Room air enters through the front opening and leaves through HEPA filtration, so the enclosure is intended for processes where protecting the sample from incoming air is not required.

Các tính năng chính

Compact operator station

The two-foot format concentrates containment around a small apparatus or a limited sample-handling task.

Personnel-focused airflow

Inward airflow at the open front helps keep process aerosols from moving into the room.

Flexible exhaust arrangement

The cabinet may operate as a recirculating enclosure or be connected through a suitable exhaust canopy.

Thông số kỹ thuật

Nominal Work Width610 mm
Cabinet ClassClass I
Inflow Velocity0.38-0.53 m/s
Pressure ModeNegative relative to the room
Exhaust FilterHEPA, nominal 99.99% efficiency at 0.3 µm
Airflow ArrangementRoom inflow with filtered recirculation or canopy-connected exhaust
Product ProtectionNot provided by the Class I airflow pattern
Front AccessSingle operator opening
Typical Work PositionCompact one-person bench procedure
Tùy chỉnhExhaust connection and work-zone services can be configured for the intended procedure and room conditions.

Applications

Small microbiology preparations, aerosol-generating equipment enclosures and sample handling in BSL-1 to BSL-3 laboratories when product protection is not required.

Solutions for Your Application

A compact laboratory needs containment without allocating space for a full-width cabinet.Use the 610 mm work zone for one defined operation and keep unrelated equipment outside the enclosure.
The process may release aerosols toward the operator.Maintain the specified inward airflow and verify that the front opening remains unobstructed during use.

Các tùy chọn có sẵn

A recirculating exhaust arrangement, a canopy connection and work-zone service fittings may be selected to suit the laboratory layout.

Planning a Class I Biological Safety Cabinet 600 mm specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.