Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Trang chủ / Sản phẩm / Thiết bị phòng sạch / Aseptic Laminar Flow Workstation 4 ft
STJH-ASEPTIC-LAMINAR-WORKSTATION-4FT

Aseptic Laminar Flow Workstation 4 ft

A standard four-foot aseptic workstation for routine sterile preparation and non-hazardous pharmacy compounding.
  • 47 in standard cabinet width
  • 720 CFM at 90 fpm
  • 44.5 in working dimension
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The four-foot model expands the published A dimension to 47 in and the E dimension to 44.5 in. It supplies approximately 720 CFM at 90 fpm through an aerosol-challenged HEPA filter and creates a positive-pressure ISO Class 5 stainless work zone. This middle size balances operator reach with space for preparation tools and component staging.

Các tính năng chính

Routine preparation capacity

The four-foot interior separates incoming supplies, active work and completed preparations.

Positive-pressure product protection

HEPA-filtered airflow sweeps the critical work zone and reduces particle deposition.

Durable stainless workspace

The stainless interior supports frequent cleaning in pharmacy and life-science use.

Thông số kỹ thuật

Published Dimensions A/B/C47 x 24.25 x 28 in
Published Dimension E44.5 in
Average Airflow720 CFM at 90 fpm
Final FilterHEPA, 99.99% at 0.3 µm
Work-Zone ConditionISO Class 5
Electrical Supply115 V, 60 Hz, 8.0 A
Heat Load1200 BTU/h
Shipping Weight370 lb
ConstructionWelded steel with stainless work area
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Applications

For routine sterile preparation, media work and non-hazardous compounding that need a four-foot protected zone. Establish an orderly workflow and keep critical sites upstream of large objects.

Solutions for Your Application

The three-foot model lacks room to separate supplies from active work.Use the 44.5 in working dimension to establish distinct staging and critical zones.
Equipment heat may burden the local room cooling system.Include the published 1200 BTU/h module heat load when planning the space.

Các tùy chọn có sẵn

Select base, electrical connection, lighting and work-zone accessories. Utility positions can be arranged around the intended sterile preparation sequence.

Planning a Aseptic Laminar Flow Workstation 4 ft specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat