A standard four-foot aseptic workstation for routine sterile preparation and non-hazardous pharmacy compounding.
  • 47 in standard cabinet width
  • 720 CFM at 90 fpm
  • 44.5 in working dimension
Solicite um orçamento. Browse produtos

Introdução do produto

The four-foot model expands the published A dimension to 47 in and the E dimension to 44.5 in. It supplies approximately 720 CFM at 90 fpm through an aerosol-challenged HEPA filter and creates a positive-pressure ISO Class 5 stainless work zone. This middle size balances operator reach with space for preparation tools and component staging.

Características-chave

Routine preparation capacity

The four-foot interior separates incoming supplies, active work and completed preparations.

Positive-pressure product protection

HEPA-filtered airflow sweeps the critical work zone and reduces particle deposition.

Durable stainless workspace

The stainless interior supports frequent cleaning in pharmacy and life-science use.

Parâmetros técnicos

Published Dimensions A/B/C47 x 24.25 x 28 in
Published Dimension E44.5 in
Average Airflow720 CFM at 90 fpm
Final FilterHEPA, 99.99% at 0.3 µm
Work-Zone ConditionISO Class 5
Electrical Supply115 V, 60 Hz, 8.0 A
Heat Load1200 BTU/h
Shipping Weight370 lb
ConstructionWelded steel with stainless work area
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Applications

For routine sterile preparation, media work and non-hazardous compounding that need a four-foot protected zone. Establish an orderly workflow and keep critical sites upstream of large objects.

Solutions for Your Application

The three-foot model lacks room to separate supplies from active work.Use the 44.5 in working dimension to establish distinct staging and critical zones.
Equipment heat may burden the local room cooling system.Include the published 1200 BTU/h module heat load when planning the space.

Opções disponíveis

Select base, electrical connection, lighting and work-zone accessories. Utility positions can be arranged around the intended sterile preparation sequence.

Planning a Aseptic Laminar Flow Workstation 4 ft specification?