Uncoated chamber face
The exposed metal avoids relying on an interior paint layer in a frequently wiped entry zone.
The stainless steel air shower uses formed SUS 304 sheet for its exposed chamber construction, with a brushed or satin surface rather than a decorative paint film. Door framing, return grilles and nozzle fittings complete the occupied passage. Behind the lining, a blower recirculates air through the selected prefilter and final filter before supplying the adjustable outlets. Access panels serve the filter and fan sections, while the base and outer casing can be specified separately from the chamber lining.
The exposed metal avoids relying on an interior paint layer in a frequently wiped entry zone.
Finish, internal trims and joint treatment can be specified to make cleaning residue easier to see and remove.
Replaceable filter stages can be accessed through the chosen service-side arrangement.
Separating liner, casing, base and hardware selections helps match the enclosure to its actual cleaning exposure.
Stainless construction works best when the finish and maintenance method are chosen together.
These are dry personnel-entry applications with a compatible wipe-clean routine. Wet process rooms, aggressive chemicals and hazardous powders require a separately specified equipment design.
The following material, compact-chamber and operating ranges are common selectable references for stainless personnel air showers. They are not an as-built dimensional drawing or a combined performance rating for one STjh configuration.
| Exposed Material | SUS 304 stainless steel chamber surfaces and door construction |
|---|---|
| Common Sheet Gauge | 1.2 mm stainless steel sheet option |
| Yüzey bitirme | Brushed or satin stainless steel |
| Compact Chamber Size References | Approximately 800 mm internal width, 900–1000 mm depth and 1900–2000 mm height |
| Air Circuit | Recirculating air through chamber returns and staged filtration |
| Nozzle Arrangement | Adjustable stainless steel outlets on the sides; upper outlets optional |
| Nozzle Velocity Reference | 20–25 m/s, selectable nozzle-outlet reference |
| Filtre seçenekleri | Replaceable prefilter plus HEPA H13 or H14 final element |
| Blowing Timer Reference | 10–99 s adjustable blowing interval |
| Electrical Supply Reference | 380 V AC, 50 Hz; other supply variants optional |
| Door Controls | Two-door interlock with sensor-initiated sequence |
| Maintenance Access | Separate access to filters and fan service components |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
The usual material-led arrangement uses a SUS 304 chamber, replaceable filtration, stainless nozzle fittings and controlled personnel doors. The outer casing, floor, trim details and optional automation are identified separately in the supplied configuration.
Specify the chamber lining, outer casing, doors, base, grilles, nozzles and fasteners separately. A stainless interior with a painted outer casing is different from an all-stainless enclosure. Match the requested brushed appearance across exposed parts, and identify whether the order retains SUS 304 or uses a selected SUS 316L alternative for a more demanding cleaning environment.
Assess the actual detergent or disinfectant concentration, contact time and temperature. Chloride-bearing residue and trapped liquid can attack stainless steel; SUS 304 is not resistant to every cleaning chemical. Use compatible non-abrasive cleaning tools and prevent ordinary steel particles from being rubbed into the surface. A stainless shell does not make the motor, controls, filters, seals or complete machine suitable for hose-down or pressure washing.
Choose the chamber around the intended number of people, gowning movement and door clearances. Internal standing width is not the net door opening, and neither is the overall enclosure width. Reserve access for removing filters, working on the blower and opening panels without entering a process operation. A floorless route or textured metal base changes the threshold and cleaning detail.
Agree the entry direction, timer, door release and emergency response with the surrounding gowning procedure. Keep return paths clear and use the selected nozzle arrangement on exposed garment surfaces. HEPA filter class does not establish a room cleanliness class, and dry air jets are not sterilisation or hazardous-powder containment. Where a long personnel passage is needed instead of a compact entry chamber, compare the walk-through cleanroom air shower tunnel.
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.